Publication:
Design of a 27-level cascaded converter as FACTS device for voltage sag mitigation

Date
2015
Authors
Nikouei B.
Tan N.M.L.
Taghizadeh S.F.
Younis M.A.A.
Journal Title
Journal ISSN
Volume Title
Publisher
Taylor and Francis Ltd.
Research Projects
Organizational Units
Journal Issue
Abstract
One of the major problems with power quality is the voltage sag phenomena. There are various solutions for sag mitigation in the power system at the transmission voltage level, but the most common way is by installing mitigating devices in the system such as Flexible AC Transmission System (FACTS). This paper proposes a three-phase 27-level converter with unequal DC sources as a static synchronous series compensator (SSSC) for voltage sag mitigation at the transmission voltage level. This paper presents the design and control of a 27-level cascaded converter with unequal DC sources without using filters and have a fast response. This paper also shows the feasibility of the control for the 27-level cascaded converter with unequal DC sources as FACTS devices using the PSCAD software. � 2015 � 2015 Engineers Australia.
Description
Electric power transmission; Power control; Power converters; Static synchronous compensators; Voltage stabilizing circuits; Cascaded converters; Design and control; Flexible ac transmission system (FACTS); Mitigating devices; Sag mitigation; Static synchronous series compensator; Transmission voltage; Voltage sag mitigation; Flexible AC transmission systems