Publication:
Failure investigation on reheater tube due to deposit and wall thinning

Date
2009
Authors
Purbolaksono J.
Tarlochan F.
Rahman M.M.
Nordin N.F.
Ahmad B.
Journal Title
Journal ISSN
Volume Title
Publisher
Research Projects
Organizational Units
Journal Issue
Abstract
Failure analysis of a reheater tube showed that the failure was caused by overheating and wall thinning. Finite element modeling, dimensional measurements, and microscopic examinations were performed to investigate the root cause of the failure. Wall thinning, due to excessive coal-ash corrosion, and overheating, due to scale buildup on the tube were measured, and estimations, the average corrosion and scale growth rates, were made. The combination of excessive scale formation on the inner tube surfaces and wall thinning due to coal-ash corrosion on the outer tube surfaces combined to cause the failure of the reheater tube. � 2009 ASM International.
Description
Keywords
Boiler material , Deposits , Failure analysis , High temperature , Thinning , Tube burst , Boiler deposits , Boilers , Corrosion , Failure analysis , Microscopic examination , Safety factor , Scale (deposits) , Tubes (components) , Boiler material , Dimensional measurements , Failure investigation , Finite element modeling , High temperature , Inner tubes , Reheater tubes , Root cause , Scale formation , Thinning , Tube burst , Wall thinning , Quality assurance
Citation