Publication:
The Effect of Mortar Grade and Thickness on the Impact Resistance of Ferrocement Slab

dc.citedby4
dc.contributor.authorMuda Z.C.en_US
dc.contributor.authorSyamsir A.en_US
dc.contributor.authorMustapha K.N.en_US
dc.contributor.authorSulleman S.en_US
dc.contributor.authorBeddu S.en_US
dc.contributor.authorThiruchelvam S.en_US
dc.contributor.authorIsmail F.B.en_US
dc.contributor.authorUsman F.en_US
dc.contributor.authorMohd Kamal N.L.en_US
dc.contributor.authorAlam M.A.en_US
dc.contributor.authorBirima A.H.en_US
dc.contributor.authorItam Z.en_US
dc.contributor.authorZaroog O.S.en_US
dc.contributor.authorid55812444000en_US
dc.contributor.authorid57195320482en_US
dc.contributor.authorid26032672000en_US
dc.contributor.authorid57189247033en_US
dc.contributor.authorid55812080500en_US
dc.contributor.authorid55812442400en_US
dc.contributor.authorid58027086700en_US
dc.contributor.authorid55812540000en_US
dc.contributor.authorid56239107300en_US
dc.contributor.authorid57199298044en_US
dc.contributor.authorid23466519000en_US
dc.contributor.authorid55102723400en_US
dc.contributor.authorid57189246634en_US
dc.date.accessioned2023-05-29T06:12:07Z
dc.date.available2023-05-29T06:12:07Z
dc.date.issued2016
dc.descriptionConcrete slabs; Cracks; Drops; Mesh generation; Reinforced concrete; Reinforcement; Drop weight impact; Linear correlation; Low impacts; Mesh reinforcement; Mesh spacing; Projectile tests; Slab thickness; Steel balls; Mortar; cement; concrete; cracking; impact; loading; mortar; spacing; steel structure; weighten_US
dc.description.abstractThis paper investigate the effect of the thickness and mesh spacing on the impact of ferrocement for the concrete slab of 300mm � 300mm size reinforced subjected to low impact projectile test. A self-fabricated drop-weight impact test rig with a steel ball weight of 1.236 kg drop at height of 150 mm, 350mm, and 500mm has been used in this research work. The objective of this research is to study the relationship of impact resistance of ferrocement against the mortar grade and slab thickness. There is a good linear correlation between impact resistance of ferrocement against the mortar grade and the thickness of ferrocement slab. The first and ultimate crack impact resistance of mortar grade 43 (for 40 mm thick slab with mesh reinforcement) are 1.60 times and 1.53 times respectively against the mortar grade 17 slab (of same thickness with mesh reinforcement). The first and ultimate crack impact resistance for 40 mm thick slab (mortar grade 43 with mesh reinforcement) are 3.55 times and 4.49 times respectively against the 20 mm thick slab (of same mortar grade with mesh reinforcement).en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo12029
dc.identifier.doi10.1088/1755-1315/32/1/012029
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84966632289
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84966632289&doi=10.1088%2f1755-1315%2f32%2f1%2f012029&partnerID=40&md5=a1f1e7f49e068cd88578c1f25c67427d
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/22766
dc.identifier.volume32
dc.publisherInstitute of Physics Publishingen_US
dc.relation.ispartofAll Open Access, Bronze
dc.sourceScopus
dc.sourcetitleIOP Conference Series: Earth and Environmental Science
dc.titleThe Effect of Mortar Grade and Thickness on the Impact Resistance of Ferrocement Slaben_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections