Publication:
A Guideline of Ultrasonic Inspection on Butt Welded Plates

dc.citedby1
dc.contributor.authorBurhan I.en_US
dc.contributor.authorMutaiyah G.en_US
dc.contributor.authorHashim D.I.en_US
dc.contributor.authorLoganathan T.M.en_US
dc.contributor.authorSultan M.T.H.en_US
dc.contributor.authorid55232553900en_US
dc.contributor.authorid57209890286en_US
dc.contributor.authorid57209882684en_US
dc.contributor.authorid35362386500en_US
dc.contributor.authorid57208100518en_US
dc.date.accessioned2023-05-29T07:29:57Z
dc.date.available2023-05-29T07:29:57Z
dc.date.issued2019
dc.descriptionButt welding; Defects; Inspection; Nondestructive examination; Welded steel structures; X ray films; X ray radiography; Double v; Mathematical formulas; Radiographic films; Radiographic inspection; Stand-off; Ultrasonic inspections; Ultrasonic techniques; Welded plates; Ultrasonic testingen_US
dc.description.abstractThis paper explained the procedure to carry out the ultrasonic inspection for single and double-V butt welded plates in detail by including the calculation of skip distance, stand-off, interpretation from plotting system, and the preparation of full inspection report as well. In addition, few inspections were compared on butt welded plate single and double-V to determine which is the most suitable, accurate and precise reading obtained. The comparisons were made between scheme answer from Sirim inspector, X-ray film, data that obtained from ultrasonic inspection and calculation by mathematical formulas and using plotting system. Mathematical formulas and plotting system was utilized to obtained the distance of stand-off (Soff) and skip distance, (Smax) whereas the plotting system were applied to locate the defects based on their S max and S off, and also to determine the depth, d and radius, r. The defects of single-V and double-V butt welding inspected by the ultrasonic technique were then compared with those obtained from the radiographic film while a good agreement was observed. However, the ultrasonic inspection proved to be much more sensitive than the radiographic inspection. � Published under licence by IOP Publishing Ltd.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo12002
dc.identifier.doi10.1088/1757-899X/554/1/012002
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85069004949
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85069004949&doi=10.1088%2f1757-899X%2f554%2f1%2f012002&partnerID=40&md5=5025776b2ebfa3924a5553cc599640b6
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/24989
dc.identifier.volume554
dc.publisherInstitute of Physics Publishingen_US
dc.relation.ispartofAll Open Access, Bronze
dc.sourceScopus
dc.sourcetitleIOP Conference Series: Materials Science and Engineering
dc.titleA Guideline of Ultrasonic Inspection on Butt Welded Platesen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files