Publication:
Performance of environmental and energy audit for manufacturing industrial buildings

dc.citedby3
dc.contributor.authorAb Wahab N.en_US
dc.contributor.authorSahril N.A.en_US
dc.contributor.authorAmiruddin A.en_US
dc.contributor.authorYasin Z.M.en_US
dc.contributor.authorSalim N.A.en_US
dc.contributor.authorRahmat N.A.en_US
dc.contributor.authorAziz N.F.A.en_US
dc.contributor.authorid35790572400en_US
dc.contributor.authorid57493895900en_US
dc.contributor.authorid55810695200en_US
dc.contributor.authorid57211410254en_US
dc.contributor.authorid36806685300en_US
dc.contributor.authorid55647163881en_US
dc.contributor.authorid57221906825en_US
dc.date.accessioned2023-05-29T06:50:32Z
dc.date.available2023-05-29T06:50:32Z
dc.date.issued2018
dc.description.abstractEnvironmental and energy audit of industrial building is important as it may help in providing a comfortable workplace for the staff as well as to observe the company�s environmental practices during operational hours while managing the energy usage in an efficient manner. It is also important in ensuring the company comply with applicable laws and regulations This paper discusses on the environmental and energy audit to identify the performance of environmental and energy efficiency in two manufacturing industrial buildings with heavy machineries. Analyses on the energy performance, visual comfort and thermal improvement including recommended solutions for optimization of energy efficiency and environmental aspects of the two buildings are presented. Energy efficiency and environmental aspects covered in this audit study are the illuminance of the building, indoor building temperature, relative humidity and carbon dioxide (CO2) percentage in indoor air quality. Jabatan Kerja Raya (JKR) standards is used as a benchmark to observe the illuminance of the buildings, Malaysian Standard 1525 (MS1525) is used as a quality control for temperature and relative humidity, while Department of Occupational Safety and Health, 2005 (DOSH 2005) is used as a quality control for CO2 percentage in air. Based on the results from the audit, the performance for both industrial building is compared. It was found that the energy efficiency and environmental performance for Factory A is better than Factory B. � 2018 Institute of Advanced Engineering and Science.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.11591/ijeecs.v12.i2.pp534-541
dc.identifier.epage541
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85064758677
dc.identifier.spage534
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85064758677&doi=10.11591%2fijeecs.v12.i2.pp534-541&partnerID=40&md5=d22b495bb46d20f04804f822a095a295
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23617
dc.identifier.volume12
dc.publisherInstitute of Advanced Engineering and Scienceen_US
dc.relation.ispartofAll Open Access, Hybrid Gold, Green
dc.sourceScopus
dc.sourcetitleIndonesian Journal of Electrical Engineering and Computer Science
dc.titlePerformance of environmental and energy audit for manufacturing industrial buildingsen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections