Publication:
A Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurations

dc.citedby1
dc.contributor.authorRadzai M.H.M.en_US
dc.contributor.authorLim C.W.en_US
dc.contributor.authorYaw C.T.en_US
dc.contributor.authorKoh S.P.en_US
dc.contributor.authorAhmad N.A.en_US
dc.contributor.authorShakeri M.en_US
dc.contributor.authorPasupuleti J.en_US
dc.contributor.authorid57226596398en_US
dc.contributor.authorid35722335000en_US
dc.contributor.authorid36560884300en_US
dc.contributor.authorid22951210700en_US
dc.contributor.authorid57220974921en_US
dc.contributor.authorid55433849200en_US
dc.contributor.authorid11340187300en_US
dc.date.accessioned2023-05-29T09:41:43Z
dc.date.available2023-05-29T09:41:43Z
dc.date.issued2022
dc.description.abstractRadiant cooling systems are commonly applied in commercial applications because of their energy-saving potential. This potential can be further enhanced by evaluating the cooling performance of the radiant cooling panel in terms of flow configurations. Although studies have been conducted on the flow configurations of the radiant cooling panel, the most suitable flow configurations have yet to be determined. The conventional serpentine flow configuration does not bring out the best cooling performance of the radiant cooling panel, therefore different flow configurations are still needed to be explored. This study conducted a quick literature review on the different radiant cooling systems as well as radiant cooling panel with different chilled water pipe configurations. The objective of this review is to provide a brief comparison of the performance of radiant cooling panel with different chilled water pipe configurations and to suggest further studies for the system development. The cooling characteristics and heat transfer of the panel are investigated by using numerical study. A comparison between the designs of flow configurations is presented. In all of the cases, the plate area and flow volume are fixed. Based on the findings obtained, applying a different chilled water pipe configuration on the radiant cooling panel will affect the flow uniformity and also the temperature distribution uniformity. An optimized flow configurations for the radiant cooling panel is important for enhancing the overall efficiency of the system � 2022,Journal of Advanced Research in Fluid Mechanics and Thermal Sciences.All Rights Reserveden_US
dc.description.natureFinalen_US
dc.identifier.doi10.37934/arfmts.89.2.114
dc.identifier.epage14
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85125180852
dc.identifier.spage1
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85125180852&doi=10.37934%2farfmts.89.2.114&partnerID=40&md5=d1e47ecf0484aee6482900d33c3afcef
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/27257
dc.identifier.volume89
dc.publisherPenerbit Akademia Baruen_US
dc.relation.ispartofAll Open Access, Hybrid Gold
dc.sourceScopus
dc.sourcetitleJournal of Advanced Research in Fluid Mechanics and Thermal Sciences
dc.titleA Brief Review on Radiant Cooling Panel with Different Chilled Water Pipe Configurationsen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections