Publication:
CFD analysis of temperature imbalance in superheater/reheater region of tangentially coal-fired boiler

dc.citedby1
dc.contributor.authorZainudin A.F.en_US
dc.contributor.authorHasini H.en_US
dc.contributor.authorFadhil S.S.A.en_US
dc.contributor.authorid57194030184en_US
dc.contributor.authorid6507435998en_US
dc.contributor.authorid55812738800en_US
dc.date.accessioned2023-05-29T06:37:39Z
dc.date.available2023-05-29T06:37:39Z
dc.date.issued2017
dc.descriptionCoal fired boilers; Computational fluid dynamics; Engineering research; Fossil fuel power plants; Superheaters; CFD analysis; Cross sectional area; Flue gas temperatures; Gain insight; Imbalance problem; Steam temperature; Tube leaks; Velocity deviation; Boilersen_US
dc.description.abstractThis paper presents a CFD analysis of the flow, velocity and temperature distribution in a 700 MW tangentially coal-fired boiler operating in Malaysia. The main objective of the analysis is to gain insights on the occurrences in the boiler so as to understand the inherent steam temperature imbalance problem. The results show that the root cause of the problem comes from the residual swirl in the horizontal pass. The deflection of the residual swirl due to the sudden reduction and expansion of the flow cross-sectional area causes velocity deviation between the left and right side of the boiler. This consequently results in flue gas temperature imbalance which has often caused tube leaks in the superheater/reheater region. Therefore, eliminating the residual swirl or restraining it from being diverted might help to alleviate the problem. � 2017 Published under licence by IOP Publishing Ltd.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo12062
dc.identifier.doi10.1088/1757-899X/257/1/012062
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85034974521
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85034974521&doi=10.1088%2f1757-899X%2f257%2f1%2f012062&partnerID=40&md5=750c328c478e7ea3072fe76cca2f5e5e
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23067
dc.identifier.volume257
dc.publisherInstitute of Physics Publishingen_US
dc.relation.ispartofAll Open Access, Gold
dc.sourceScopus
dc.sourcetitleIOP Conference Series: Materials Science and Engineering
dc.titleCFD analysis of temperature imbalance in superheater/reheater region of tangentially coal-fired boileren_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections