Publication:
PARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONS

dc.citedby0
dc.contributor.authorHassan W.en_US
dc.contributor.authorHussain G.A.en_US
dc.contributor.authorFiruzi K.en_US
dc.contributor.authorAriffin A.M.en_US
dc.contributor.authorKay J.A.en_US
dc.contributor.authorid56038670200en_US
dc.contributor.authorid57203105565en_US
dc.contributor.authorid57969834100en_US
dc.contributor.authorid16400722400en_US
dc.contributor.authorid8853452700en_US
dc.date.accessioned2025-03-03T07:44:47Z
dc.date.available2025-03-03T07:44:47Z
dc.date.issued2024
dc.description.abstractIn this paper the effect of contamination under varying temperature and relative humidity (RH) in electrical electric motors? (EM) insulation is investigated through partial discharge (PD) diagnostics. The variations in PD intensity have been investigated under varying environmental conditions. For this purpose, PD measurements were carried out within an artificial industrial environment inside a climate-controlled chamber. Various PD features were extracted to study probability distribution functions to further investigate the PD severity at various levels of contamination, under varying temperatures and RH. Based on the experimental outcomes, it was revealed that PD activity within the EM insulation was significantly affected by temperature and RH under varying contamination conditions. The proposed methodology is believed to be helpful in achieving the desired level of reliability for a wide range of industrial applications exposed to ambient stresses. ?2024 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.1109/PCIC47799.2024.10832267
dc.identifier.scopus2-s2.0-85217165358
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85217165358&doi=10.1109%2fPCIC47799.2024.10832267&partnerID=40&md5=f36abcdbb793e393490579005780a6ff
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/36803
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceScopus
dc.sourcetitleRecord of Conference Papers - Annual Petroleum and Chemical Industry Conference
dc.subjectElectric machine insulation
dc.subjectElectric motors
dc.subjectPartial discharges
dc.subjectPetroleum tar
dc.subjectAmbient stress
dc.subjectAmbients
dc.subjectElectric motor insulation
dc.subjectExposed to
dc.subjectIndustrial operations
dc.subjectMotor insulation
dc.subjectPartial discharge measurements
dc.subjectRelative humidity
dc.subjectTemperature and relative humidity
dc.subjectVarying temperature
dc.subjectDistribution functions
dc.titlePARTIAL DISCHARGE DIAGNOSTICS IN ELECTRIC MOTORS EXPOSED TO AMBIENT STRESSES DURING INDUSTRIAL OPERATIONSen_US
dc.typeConference paperen_US
dspace.entity.typePublication
Files