Publication:
Modelling and simulation of variable speed pico hydel energy storage system for microgrid applications

dc.citedby28
dc.contributor.authorKrishnakumar R. V.en_US
dc.contributor.authorVigna K.R.en_US
dc.contributor.authorGomathi V.en_US
dc.contributor.authorEkanayake J.B.en_US
dc.contributor.authorTiong S.K.en_US
dc.contributor.authorid57218793243en_US
dc.contributor.authorid6602912020en_US
dc.contributor.authorid56036455200en_US
dc.contributor.authorid7003409510en_US
dc.contributor.authorid15128307800en_US
dc.date.accessioned2023-05-29T07:24:23Z
dc.date.available2023-05-29T07:24:23Z
dc.date.issued2019
dc.descriptionEnergy storage; Hierarchical systems; Hydraulic motors; MATLAB; Maximum power point trackers; Natural resources; Regression analysis; Renewable energy resources; Speed; Stochastic systems; Energy storage systems; Hydro storage systems; Maximum Power Point Tracking; Micro grid; Variable speed; Adaptive control systemsen_US
dc.description.abstractThe scheduling and dispatch of stochastic renewable energy sources can be difficult in a Microgrid (MG). Renewable energy sources can power the MG reliably if supported by energy storage systems, via hierarchical control of the MG. In this work, a sustainable energy storage system is modelled with the existing resources in an agricultural farm. The resource is a downscaled pumped hydro storage system called Pico Hydel Energy Storage System (PHESS). The PHESS is numerically modelled with the governing equations of various components in the system. The proposed configuration caters for the water demand of crops and the energy storage requirement in a renewable energy powered microgrid. A full scale power converter topology is employed for variable speed operation of the proposed energy storage system. The power absorbed from the microgrid and injected into the microgrid is controlled by adjusting the speed of PHESS. An adaptive perturb and observe algorithm is developed to control the storage system in the generating mode, thus enabling the maximum extraction of power at various discharge rates and hydraulic head. A relationship between the power and speed of the turbine is deduced through regression analysis to control the storage system in pumping mode. The proposed model of PHESS is optimized to accept power commands directly from the MG controller for various levels of controls in the MG thus ensuring plug and play feature. The results obtained from MATLAB/Simulink software justify the effectiveness of the control strategies in both modes of operation. � 2019 Elsevier Ltden_US
dc.description.natureFinalen_US
dc.identifier.ArtNo100808
dc.identifier.doi10.1016/j.est.2019.100808
dc.identifier.scopus2-s2.0-85068159382
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85068159382&doi=10.1016%2fj.est.2019.100808&partnerID=40&md5=8d12e4cd220b095ed920df10c028a8a2
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/24542
dc.identifier.volume24
dc.publisherElsevier Ltden_US
dc.sourceScopus
dc.sourcetitleJournal of Energy Storage
dc.titleModelling and simulation of variable speed pico hydel energy storage system for microgrid applicationsen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections