Electrical field of electrical appliances versus distance: A preliminary analysis

dc.citedby1
dc.contributor.authorMustafa N.B.A.en_US
dc.contributor.authorNordin F.H.en_US
dc.contributor.authorIsmail F.A.A.en_US
dc.contributor.authorAlkahtani A.A.en_US
dc.contributor.authorBalasubramaniam N.en_US
dc.contributor.authorHock G.C.en_US
dc.contributor.authorShariff Z.A.M.en_US
dc.contributor.authorid57191952020en_US
dc.contributor.authorid25930510500en_US
dc.contributor.authorid55812369000en_US
dc.contributor.authorid55646765500en_US
dc.contributor.authorid26967610800en_US
dc.contributor.authorid16021614500en_US
dc.contributor.authorid55812833700en_US
dc.date.accessioned2023-12-29T07:45:13Z
dc.date.available2023-12-29T07:45:13Z
dc.date.issued2013
dc.description.abstractEvery household electrical appliance that is plugged in emits electric field even if it is not operating. The source where the appliance is plugged into and the components of household electrical appliance contribute to electric field emission. The electric field may cause unknown disturbance to the environment or also affect the human health and the effect might depends on the strength of the electric field emitted by the appliance. This paper will investigate the strength of the electric field emitted by four different electrical appliances using spectrum analyser. The strength will be captured at three different distances; (i) 1m (ii) 2m and (iii) 3m and analysis of the strength of the electrical field is done based on the three different distances. The measurement results show that the strength of the electric field is strongest when it is captured at 1m and the weakest at 3m from the electrical appliance. The results proved that the farther an object is located from the electrical appliance; the less effect the magnetic field has. � Published under licence by IOP Publishing Ltd.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo12097
dc.identifier.doi10.1088/1755-1315/16/1/012097
dc.identifier.issue1
dc.identifier.scopus2-s2.0-84881104645
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84881104645&doi=10.1088%2f1755-1315%2f16%2f1%2f012097&partnerID=40&md5=788a07ce38e54da729b0cedb56bbe6a5
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/30172
dc.identifier.volume16
dc.publisherInstitute of Physics Publishingen_US
dc.relation.ispartofAll Open Access; Gold Open Access
dc.sourceScopus
dc.sourcetitleIOP Conference Series: Earth and Environmental Science
dc.subjectSpectrum analyzers
dc.subjectElectrical appliances
dc.subjectElectrical field
dc.subjectHousehold electrical appliances
dc.subjectHuman health
dc.subjectMeasurement results
dc.subjectPreliminary analysis
dc.subjectUnknown disturbance
dc.subjectelectric field
dc.subjectenergy efficiency
dc.subjectmagnetic field
dc.subjectspectrum
dc.subjectElectric fields
dc.titleElectrical field of electrical appliances versus distance: A preliminary analysisen_US