Publication:
Identification of Leaflet Using Pixel Tracker Technique in Echocardiogram

dc.contributor.authorNasir N.R.M.en_US
dc.contributor.authorRahmat R.W.O.K.en_US
dc.contributor.authorSulaiman P.S.en_US
dc.contributor.authorKadiman S.en_US
dc.contributor.authorDimon M.Z.en_US
dc.contributor.authorid57076901800en_US
dc.contributor.authorid35614233000en_US
dc.contributor.authorid55758117300en_US
dc.contributor.authorid58100013500en_US
dc.contributor.authorid25958964000en_US
dc.date.accessioned2023-05-29T07:30:21Z
dc.date.available2023-05-29T07:30:21Z
dc.date.issued2019
dc.descriptionDecision making; Diagnosis; Echocardiography; Petroleum reservoir evaluation; Pixels; Surgery; Tracking (position); 3D echocardiography; Decision making process; Medical fields; Surgical techniques; Tracking techniques; Transesophageal (TEE); Transesophageal echocardiographies; Tricuspid valve; Image enhancementen_US
dc.description.abstractIn the past decades, echocardiography has appeared as an important modality in medical field to assess heart�s function and structures as well as for diagnosis and evaluation. Many image processing researches are done to enhance the imaging aspect and produce better quality of image. Accurateness in measuring tricuspid valve is an important issue, not only for surgical decision-making process but also in deciding the suitable surgical technique on patient such as valve implication or ring placement. In this paper, we will discuss on techniques that have been applied recently in detection of tricuspid valve�s leaflets and as for experiment, three dimensional transesophageal echocardiography images were used using pixel tracking technique and thin tissue detector. Our findings will be focusing more on those techniques applied on 3D echocardiography images from different angels and positions. � 2019, Springer Nature Switzerland AG.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.1007/978-3-030-20717-5_11
dc.identifier.epage98
dc.identifier.scopus2-s2.0-85066147046
dc.identifier.spage93
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85066147046&doi=10.1007%2f978-3-030-20717-5_11&partnerID=40&md5=951f1c37eaeca6b78dd6ec1ceb113f93
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25012
dc.identifier.volume565
dc.publisherSpringer Verlagen_US
dc.sourceScopus
dc.sourcetitleLecture Notes in Electrical Engineering
dc.titleIdentification of Leaflet Using Pixel Tracker Technique in Echocardiogramen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections