Publication:
Numerical relay for overcurrent protection using TMS320F2812

dc.citedby8
dc.contributor.authorGoh Y.L.en_US
dc.contributor.authorRamasamy A.K.en_US
dc.contributor.authorNagi F.H.en_US
dc.contributor.authorAbidin A.A.Z.en_US
dc.contributor.authorid36871489800en_US
dc.contributor.authorid16023154400en_US
dc.contributor.authorid56272534200en_US
dc.contributor.authorid25824750400en_US
dc.date.accessioned2023-12-29T07:49:57Z
dc.date.available2023-12-29T07:49:57Z
dc.date.issued2010
dc.description.abstractOvercurrent protection is a very important element in power systems. This protection is essential in order to minimize disturbances caused by any failure in the system and to ensure continuous power delivery. Overcurrent relays are one of the devices used to achieve these purposes. The overcurrent relays initiate the corrective mechanism to determine the operation time of the relay. Thus, the overcurrent relays must have high reliability and accuracy to detect any fault currents present and determine the operation time. The entire system will be tremendously affected if the relays fail to trip or cause mal-tripping. An overcurrent relay is implemented on a high speed and high performance digital signal processor (DSP). The simulation was carried out using MATLAB/Simulink. Then, the relay was implemented on TMS320F2812 based on two different methods. In the first method, the relay simulation model from MATLAB/Simulink is downloaded into the DSP whereas in the second method, code in C is directly written on the DSP to represent the relay. The relay performance was compared with the IEC 255-3 standard and the outcomes obtained are encouraging.en_US
dc.description.natureFinalen_US
dc.identifier.epage50
dc.identifier.scopus2-s2.0-79959907717
dc.identifier.spage45
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-79959907717&partnerID=40&md5=a28103b7ad3a6b9033cecd954efe89d0
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/30593
dc.pagecount5
dc.sourceScopus
dc.sourcetitleInternational conference on Circuits, Systems, Electronics, Control and Signal Processing - Proceedings
dc.subjectDigital signal processors
dc.subjectOvercurrent protection
dc.subjectPower system protection
dc.subjectProtective relaying
dc.subjectComputer simulation
dc.subjectDigital circuits
dc.subjectDigital signal processors
dc.subjectElectric power transmission
dc.subjectElectric relays
dc.subjectPower transmission
dc.subjectSignal processing
dc.subjectSpeed control
dc.subjectEntire system
dc.subjectHigh reliability
dc.subjectMATLAB /simulink
dc.subjectNumerical relays
dc.subjectOperation time
dc.subjectOver current
dc.subjectOvercurrent relays
dc.subjectPower delivery
dc.subjectPower system protection
dc.subjectProtective relaying
dc.subjectSimulation model
dc.subjectTMS320F2812
dc.subjectOvercurrent protection
dc.titleNumerical relay for overcurrent protection using TMS320F2812en_US
dc.typeConference paperen_US
dspace.entity.typePublication
Files
Collections