dc.description.abstractPartial discharge (PD) is a phenomenon that causes failures in high voltage (HV) components due to the degradation of insulation. Before an interruption or fault occurs, early detection of insulation degradation is essential. However, the long-term effect of PD will lead to the failure of the power system. This is important to control and diagnose the health of the HV power equipment such as power transformer. The main issue when measuring PD is the accuracy and sensitivity of the PD detection technique. This paper consists of two parts which are classification of the PD detection technique and hybrid detection technique. In this paper, an overview of the detection technique for power transformer including optical detection, chemical detection, electrical detection, electromagnetic detection, acoustic emission detection and hybrid detection technique is presented. The hybrid detection technique is based on combining two or more stand-alone detection technique. Based on this review, the hybrid detection technique showed that the advantages of performance in terms of sensitivity and accuracy for detecting the PD in power transformer. � 2020, Institute of Advanced Scientific Research, Inc. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.5373/JARDCS/V12SP7/20202230
dc.identifier.epage1312
dc.identifier.issue7 Special Issue
dc.identifier.scopus2-s2.0-85090622699
dc.identifier.spage1302
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85090622699&doi=10.5373%2fJARDCS%2fV12SP7%2f20202230&partnerID=40&md5=5aec241b6386f592ee017465da94553c
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25678
dc.identifier.volume12
dc.publisherInstitute of Advanced Scientific Research, Inc.en_US
dc.sourceScopus
dc.sourcetitleJournal of Advanced Research in Dynamical and Control Systems
dc.titlePartial discharge signal measurement based on stand-alone and hybrid detection technique for power transformeren_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections