dc.descriptionElectric power factor; Fossil fuels; Global warming; Location; Silicon compounds; Conventional generation; Different voltages; IEEE 14 bus system; Loss minimization; Operating power; Optimal locations; Optimal placements; Voltage profile; System stabilityen_US
dc.description.abstractWith the increase in concern of global warming, most nations are pushing for a greener option to the current fossil fuel-based generation schemes. Due to its versatile opportunities, Photovoltaic (PV) installations are becoming more widespread. Unlike the conventional generation systems PV is located closer to the load centers. This gives possibility of injecting PV at optimal locations to minimize system losses and improve voltage profile. Appropriate location and size of PV is vital for the stability of the system. This paper, considers different voltage stability indices to determine precise PV location, explores effects of PV sizing and impact of PV power factor fluctuations. To validate the stability of the proposed scheme, simulation is done for IEEE 33 bus system and IEEE 14 bus system with DigSilent. When system is optimized it showed a great improvement to the voltage profile with considerable loss reduction. � 2020 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo9243100
dc.identifier.doi10.1109/SPIES48661.2020.9243100
dc.identifier.epage131
dc.identifier.scopus2-s2.0-85096917267
dc.identifier.spage126
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85096917267&doi=10.1109%2fSPIES48661.2020.9243100&partnerID=40&md5=48145b18bf3c6ab93437ec0b33aa0dff
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25247
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceScopus
dc.sourcetitle2020 2nd International Conference on Smart Power and Internet Energy Systems, SPIES 2020
dc.titleOptimal Placement, Sizing and Operating Power Factor of PV for Loss Minimization and Voltage Improvement in Distribution Network via DigSilenten_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections