Publication:
Efficacy and safety of SPRINT and STAR protocol on Malaysian critically-ill patients

dc.citedby5
dc.contributor.authorAhamad N.en_US
dc.contributor.authorRazak N.en_US
dc.contributor.authorJamaluddin U.en_US
dc.contributor.authorSuhaimi F.en_US
dc.contributor.authorPretty C.en_US
dc.contributor.authorChase G.en_US
dc.contributor.authorRalib A.en_US
dc.contributor.authorNoor B.M.en_US
dc.contributor.authorid56960410200en_US
dc.contributor.authorid37059587300en_US
dc.contributor.authorid55330889600en_US
dc.contributor.authorid36247893200en_US
dc.contributor.authorid6508290605en_US
dc.contributor.authorid35570524900en_US
dc.contributor.authorid37031770900en_US
dc.contributor.authorid57193664053en_US
dc.date.accessioned2023-05-29T06:13:11Z
dc.date.available2023-05-29T06:13:11Z
dc.date.issued2016
dc.descriptionBiomedical engineering; Intensive care units; Safety engineering; Stars; Control protocols; Critically-ill patients; Hyperglycaemia; Hypoglycaemic; Insulin infusions; Model based controls; Model-based OPC; Patient safety; Patient treatmenten_US
dc.description.abstractIntensive care unit patients may have a better glycaemic management with the right control protocol. Results of virtual trial performance on Malaysian critically-ill patients adopting a model-derived and model-based control protocol known as SPRINT and STAR are presented in this paper. These ICU patients have been treated by intensive sliding-scale insulin infusion. The effectiveness and safety of glycaemic control are then analysed. Results showed that patient safety improved by 83% with SPRINT and STAR protocol as the number of hypoglycaemic patients significantly reduced (BG<2.2 mmol/L). Percentage of time within desired bands and median BG improves in both SPRINT and STAR. However, the improvements are associated with higher number of BG measurements (workload). � 2016 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo7843476
dc.identifier.doi10.1109/IECBES.2016.7843476
dc.identifier.epage375
dc.identifier.scopus2-s2.0-85015620904
dc.identifier.spage370
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85015620904&doi=10.1109%2fIECBES.2016.7843476&partnerID=40&md5=256bc7582aa528ca2bd3e7a8759dd8fa
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/22898
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartofAll Open Access, Green
dc.sourceScopus
dc.sourcetitleIECBES 2016 - IEEE-EMBS Conference on Biomedical Engineering and Sciences
dc.titleEfficacy and safety of SPRINT and STAR protocol on Malaysian critically-ill patientsen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections