Publication:
Power Quality Performance Analysis of grid tied PV fed Parallel Pumping System under Normal and Vibrating Condition

dc.citedby5
dc.contributor.authorShankar V.K.A.en_US
dc.contributor.authorUmashankar S.en_US
dc.contributor.authorSanjeevikumar P.en_US
dc.contributor.authorMihet-Popa L.en_US
dc.contributor.authorFed�k V.en_US
dc.contributor.authorRamachandaramurthy V.K.en_US
dc.contributor.authorid57209452892en_US
dc.contributor.authorid57199091461en_US
dc.contributor.authorid18134802000en_US
dc.contributor.authorid6506881488en_US
dc.contributor.authorid56007516100en_US
dc.contributor.authorid6602912020en_US
dc.date.accessioned2023-05-29T06:56:06Z
dc.date.available2023-05-29T06:56:06Z
dc.date.issued2018
dc.descriptionCentrifugal pumps; Electric power transmission networks; Power quality; Pumping plants; Pumps; Quality control; Variable speed drives; Vibrations (mechanical); Water quality; Appropriate control methods; Control techniques; Electrical power quality; Normal condition; Parallel pumping systems; Power quality parameters; Power quality performance; Vibrations; Electric power system controlen_US
dc.description.abstractThe aim of this paper is to perform the relative study of power quality problems in a grid tied solar PV system, with and without vibration connected to a parallel pumping system at 1.0 bar set pressure by using two control techniques such as VVC+ & V/f. In case of vibrations, the effect of motor vibration problems on the dynamic performance and electrical power quality of water pumping system will be observed. Vibrations are introduced in the pumping system by loosening the base plate of the pumps. During motor vibrations, the instantaneous flicker values become high which leads to variation in the supply voltage and torque imbalance. The effect of power quality parameters in a solar feeder during normal conditions and vibrating conditions are analysed. In normal condition, the THD increases and the flicker is high only during transient period due to sudden voltage variations. A comparison has been made to observe the appropriate control method for pumping system with and without vibrations in a solar PV-grid connected system. � 2018 The Authors. Published by Elsevier Ltd.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.1016/j.egypro.2018.04.092
dc.identifier.epage503
dc.identifier.scopus2-s2.0-85056531378
dc.identifier.spage497
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85056531378&doi=10.1016%2fj.egypro.2018.04.092&partnerID=40&md5=3581345c1aded4b9a9cd7e2d7fc1a573
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/24151
dc.identifier.volume145
dc.publisherElsevier Ltden_US
dc.relation.ispartofAll Open Access, Bronze
dc.sourceScopus
dc.sourcetitleEnergy Procedia
dc.titlePower Quality Performance Analysis of grid tied PV fed Parallel Pumping System under Normal and Vibrating Conditionen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections