Publication:
Heat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)

dc.citedby0
dc.contributor.authorSingh M.S.J.en_US
dc.contributor.authorJalil N.A.A.en_US
dc.contributor.authorRahim S.A.en_US
dc.contributor.authorZulkefli Z.A.en_US
dc.contributor.authorHasini H.en_US
dc.contributor.authorid57712384500en_US
dc.contributor.authorid36942027300en_US
dc.contributor.authorid37114756400en_US
dc.contributor.authorid35340175200en_US
dc.contributor.authorid6507435998en_US
dc.date.accessioned2024-10-14T03:18:47Z
dc.date.available2024-10-14T03:18:47Z
dc.date.issued2023
dc.description.abstractThe assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP), and the influence of the ACP price on daily losses or gains are thoroughly analyzed for key performance parameters for three fixed ACP of RM12, 18, and 24 per GJ. This paper mainly investigates key parameters and related equipment that significantly affect the HR of the CFPP and ranks the parameters affecting HR from most significant to least significant. The baseline or target values are obtained from the plant commissioning manuals and the Performance Guarantee Test (PGT). Actual real-life operational data from a 700MWn CFPP is utilized to improve the accuracy and confidence levels of the results obtained. It was found that at the nominal operating baseload, the most significant negative HR deviation is for the Rotary Air Heater (RAH) gas exit temperature with a negative HR deviation of-137.9 kJ/kWh leading to an annual loss of RM17.6 million at ACP of RM24/GJ while the superheater and reheater spray flows are contributing least to the HR deviation. This analysis highlighting the impact of key parameters affecting the performance enables plant operations and maintenance teams to focus on such parameters to mitigate losses. � Universiti Putra Malaysia Press.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.47836/pjst.31.3.18
dc.identifier.epage1474
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85154544509
dc.identifier.spage1453
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85154544509&doi=10.47836%2fpjst.31.3.18&partnerID=40&md5=b93ba7656b0967cffb81d6522d94dbc7
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/34277
dc.identifier.volume31
dc.pagecount21
dc.publisherUniversiti Putra Malaysia Pressen_US
dc.relation.ispartofAll Open Access
dc.relation.ispartofHybrid Gold Open Access
dc.sourceScopus
dc.sourcetitlePertanika Journal of Science and Technology
dc.subjectApplicable coal price
dc.subjectcoal-fired power plant performance
dc.subjectheat rate
dc.subjectheat rate deviation analysis
dc.titleHeat Rate Deviation Analysis of a Coal-Fired Power Plant (CFPP) with the Influence of Applicable Coal Prices (ACP)en_US
dc.typeArticleen_US
dspace.entity.typePublication