Publication:
EXPERIMENTAL STUDY OF STRENGTHENED REINFORCED CONCRETE FLAT PLATE USING CFRP UNDER CONCENTRATED STATIC LOADS

dc.citedby0
dc.contributor.authorAbed B.R.en_US
dc.contributor.authorBeddu S.en_US
dc.contributor.authorItam Z.en_US
dc.contributor.authorKhudhair M.A.A.en_US
dc.contributor.authorid58876206100en_US
dc.contributor.authorid55812080500en_US
dc.contributor.authorid55102723400en_US
dc.contributor.authorid57218793919en_US
dc.date.accessioned2024-10-14T03:17:24Z
dc.date.available2024-10-14T03:17:24Z
dc.date.issued2023
dc.description.abstractFlat plate structures are popular in residential buildings and parking garages for their arbitrary column placement, lower story heights, smooth finishes, and quick construction. Fiber-reinforced polymers replace steel plates for reinforcing applications. This research experimentally investigated the effectiveness of strengthening and repairing reinforced concrete flat slab-to-column connections using CFRP sheets and bars. The experimental variables include the effect of CFRP laminates and CFRP bars on the punching shear behaviour of high- and normal-strength concrete and the use of CFRP laminates in both repairing and strengthening concrete. The study examines fifty scaled, strengthened, and repaired flat slab specimens. Three of these are control specimens, with no variation introduced. Four other specimens are like the control but strengthened by CFRP sheets and bars with normal-strength concrete. Four of the other specimens are like the control but strengthened by CFRP sheets and bars with medium-strength concrete, and the other specimens are like the control but strengthened by CFRP sheets and bars with high-strength concrete. The findings demonstrate that all specimens behaved similarly regarding their breaking patterns. The first crack formed on the tension side of the slabs at the area of greatest bending moment around the column at load levels between 35 and 50 kN. Cracks began to spread from the column face toward the slab edge in the direction of the unbalanced moment, or the direction of the greater depth, at higher load levels of 80 to 130 kN. � 2023 Taylor's University. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.epage162
dc.identifier.scopus2-s2.0-85184567575
dc.identifier.spage144
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85184567575&partnerID=40&md5=da38b8931a9d600eb9d9f4eb9ea1b746
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/33897
dc.identifier.volume18
dc.pagecount18
dc.publisherTaylor's Universityen_US
dc.sourceScopus
dc.sourcetitleJournal of Engineering Science and Technology
dc.subjectCarbon fibre reinforcement polymer (CFRP)
dc.subjectPunching shear
dc.subjectStrengthening slabs
dc.titleEXPERIMENTAL STUDY OF STRENGTHENED REINFORCED CONCRETE FLAT PLATE USING CFRP UNDER CONCENTRATED STATIC LOADSen_US
dc.typeArticleen_US