Publication:
Optimizing of gross pollutant trap to improve the maintenance at Sungai Bunus Malaysia

dc.citedby3
dc.contributor.authorMunir S.N.U.en_US
dc.contributor.authorSidek L.M.en_US
dc.contributor.authorHaron S.H.en_US
dc.contributor.authorSaid N.F.M.en_US
dc.contributor.authorBasri H.en_US
dc.contributor.authorAhmad R.en_US
dc.contributor.authorDom N.M.en_US
dc.contributor.authorIsmail M.A.en_US
dc.contributor.authorid57204940556en_US
dc.contributor.authorid35070506500en_US
dc.contributor.authorid56800608600en_US
dc.contributor.authorid57189243019en_US
dc.contributor.authorid57065823300en_US
dc.contributor.authorid57212461901en_US
dc.contributor.authorid57189070135en_US
dc.contributor.authorid57199850675en_US
dc.date.accessioned2023-05-29T06:50:15Z
dc.date.available2023-05-29T06:50:15Z
dc.date.issued2018
dc.description.abstractThis paper discusses the efficiency of installed Gross Pollutant Traps (GPTs) for optimizing to improve the maintenance at Sungai Bunus, Malaysia. An increasing population due to urbanization contributes to the generation of increased amounts of rubbish and waste material. The uncontrolled dumping of debris can exert a significant impact on aesthetics and river water quality, both of which affect the quality of life in urban environments and increased management costs. The performance of GPTs is strongly dependent upon the specific site criteria including type of land use, hydrological regime and maintenance frequency. The study is conducted by providing a management and planning tool for maintenance purposes of the gross pollutants in the urban areas under one of the sub-catchment in River of Life (ROL) project, namely Sungai Bunus, Malaysia. The gross pollutant wet load data was collected and analysed based on maintenance data from January 2015 to December 2016 for a total number of 55 proprietary GPTs. The data collected from gross pollutant wet load was found to be trapped inside the GPTs from different types of land use which is residential, commercial and mixed development. Apart from that, simple calculation on the optimum number is calculated by comparing with other countries which are Spring and Capetown, South Africa and Australia. The result shows the reduction 47.21% of the average wet load from the year 2015 to 2016. The contribution from each type of land use shows 51.37% of the source of gross pollutants in Sg Bunus, Malaysia comes from residential area followed by mixed development and commercial area with the percentage contribution of 37.17% and 11.46% respectively. The optimum numbers of gross pollutant trap need to be added based on comparing with other countries was Spring South Africa (55 GPTs), Cape Town South Africa (194 GPTs) and Australia (199 GPTs). From the results, the frequency maintenance was every two month for Sungai Bunus Malaysia. � 2018 Author(s).en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo20204
dc.identifier.doi10.1063/1.5066845
dc.identifier.scopus2-s2.0-85058052183
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85058052183&doi=10.1063%2f1.5066845&partnerID=40&md5=de6f5b8cf8c18561e18efa6c3eb15fee
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23566
dc.identifier.volume2030
dc.publisherAmerican Institute of Physics Inc.en_US
dc.sourceScopus
dc.sourcetitleAIP Conference Proceedings
dc.titleOptimizing of gross pollutant trap to improve the maintenance at Sungai Bunus Malaysiaen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections