Publication:
Determination of Soil Moisture Content using Laboratory Experimental and Field Electrical Resistivity Values

dc.contributor.authorHazreek Z.A.M.en_US
dc.contributor.authorRosli S.en_US
dc.contributor.authorFauziah A.en_US
dc.contributor.authorWijeyesekera D.C.en_US
dc.contributor.authorAshraf M.I.M.en_US
dc.contributor.authorFaizal T.B.M.en_US
dc.contributor.authorKamarudin A.F.en_US
dc.contributor.authorRais Y.en_US
dc.contributor.authorMd Dan M.F.en_US
dc.contributor.authorAzhar A.T.S.en_US
dc.contributor.authorHafiz Z.M.en_US
dc.contributor.authorid54394805800en_US
dc.contributor.authorid36675436700en_US
dc.contributor.authorid7101861875en_US
dc.contributor.authorid6506086896en_US
dc.contributor.authorid57020653900en_US
dc.contributor.authorid57200258888en_US
dc.contributor.authorid56181304500en_US
dc.contributor.authorid57201776339en_US
dc.contributor.authorid55998530000en_US
dc.contributor.authorid57221094905en_US
dc.contributor.authorid39162217600en_US
dc.date.accessioned2023-05-29T06:52:18Z
dc.date.available2023-05-29T06:52:18Z
dc.date.issued2018
dc.descriptionCorrelation methods; Drilling platforms; Electric conductivity; Electric resistance; Laboratories; Moisture determination; Particle size; Particle size analysis; Soil moisture; Soil testing; Characterization tests; Civil engineering structures; Coefficient of determination; Conventional approach; Drilling techniques; Geotechnical properties; Site investigations; Statistical correlation; Soil surveysen_US
dc.description.abstractThe efficiency of civil engineering structure require comprehensive geotechnical data obtained from site investigation. In the past, conventional site investigation was heavily related to drilling techniques thus suffer from several limitations such as time consuming, expensive and limited data collection. Consequently, this study presents determination of soil moisture content using laboratory experimental and field electrical resistivity values (ERV). Field and laboratory electrical resistivity (ER) test were performed using ABEM SAS4000 and Nilsson400 soil resistance meter. Soil sample used for resistivity test was tested for characterization test specifically on particle size distribution and moisture content test according to BS1377 (1990). Field ER data was processed using RES2DINV software while laboratory ER data was analyzed using SPSS and Excel software. Correlation of ERV and moisture content shows some medium relationship due to its r = 0.506. Moreover, coefficient of determination, R2 analyzed has demonstrate that the statistical correlation obtain was very good due to its R2 value of 0.9382. In order to determine soil moisture content based on statistical correlation (w = 110.68?-0.347), correction factor, C was established through laboratory and field ERV given as 19.27. Finally, this study has shown that soil basic geotechnical properties with particular reference to water content was applicably determined using integration of laboratory and field ERV data analysis thus able to compliment conventional approach due to its economic, fast and wider data coverage. � 2018 Institute of Physics Publishing. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo12074
dc.identifier.doi10.1088/1742-6596/995/1/012074
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85046092454
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85046092454&doi=10.1088%2f1742-6596%2f995%2f1%2f012074&partnerID=40&md5=916c17dc8d980f4e7a35a08be64ad86d
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23842
dc.identifier.volume995
dc.publisherInstitute of Physics Publishingen_US
dc.relation.ispartofAll Open Access, Bronze, Green
dc.sourceScopus
dc.sourcetitleJournal of Physics: Conference Series
dc.titleDetermination of Soil Moisture Content using Laboratory Experimental and Field Electrical Resistivity Valuesen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections