dc.date.issued2013
dc.description.abstractStable operation of a power system requires a continuous match between energy input to the prime movers and the electrical load of the system. Any change of load demand must be accompanied by a corresponding change in terms of the amount of energy prime mover given to the turbine system. When a power system is subjected to significant transient disturbances, the machine may lose synchronism to the system. If this were to happen, the machine's rotor angle will undergo wide variations, voltage and frequency may deviate widely from normal values. This paper presents the applications of Area-Based Transient Stability Indexes (TSI): COI Angle and COI Speed as a new technique to evaluate the impact of disturbances to power system stability and to optimize the mechanical input power of synchronous generators in order to prevent transient instability in a power system using Evolutionary Programming (EP) approach. Transient analysis is carried out using PSS�E software on IEEE 118 Bus Test System at system conditions with various types of loads, static and dynamic. The optimization of the input power to generator is carried out using transient stability indexes as fitness functions for a three area IEEE 30 Bus and IEEE 118 Bus Test Systems respectively. Results obtained from the experiment revealed that the EP approach is able to give an optimal solution. � 2005 - 2013 JATIT & LLS. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.epage391
dc.identifier.issue3
dc.identifier.scopus2-s2.0-84881011224
dc.identifier.spage381
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84881011224&partnerID=40&md5=8b08e8f972bcfede95628e946dfc78f5
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/29397
dc.identifier.volume53
dc.pagecount10
dc.publisherAsian Research Publishing Network (ARPN)en_US
dc.sourceScopus
dc.sourcetitleJournal of Theoretical and Applied Information Technology
dc.subjectArea-based transient stability indexes: COI angle and COI speed
dc.subjectEvolutionary programming
dc.subjectOptimization