Publication:
High Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable System

dc.citedby2
dc.contributor.authorGhani A.B.A.en_US
dc.contributor.authorChakrabarty C.K.en_US
dc.contributor.authorRamasamy A.K.en_US
dc.contributor.authorAvinash A.R.en_US
dc.contributor.authorShafie H.en_US
dc.contributor.authorPermal N.en_US
dc.contributor.authorDanikas M.G.en_US
dc.contributor.authorid24469638000en_US
dc.contributor.authorid6701755282en_US
dc.contributor.authorid16023154400en_US
dc.contributor.authorid56781356900en_US
dc.contributor.authorid57207853865en_US
dc.contributor.authorid56781496300en_US
dc.contributor.authorid7003752405en_US
dc.date.accessioned2023-05-29T07:26:59Z
dc.date.available2023-05-29T07:26:59Z
dc.date.issued2019
dc.descriptionComputer software; Electric impedance measurement; Telecommunication cables; Testing; Underground cables; Distribution cables; Experimental values; High frequency alternating current; Higher frequencies; In-service failures; Insulation conditions; Measurement techniques; Underground power cable system; Cable sheathingen_US
dc.description.abstractThe aim of this paper is to show that Tan delta HFAC technique is applicable for longer cables. As underground cables are in service for years, it is necessary to carry out diagnostic test to rectify the possible problem that may occur in a cable so that precautionary action can be taken to avoid unnecessary in-service failure of the cable. One of the diagnostic testing techniques, known as Tangent Delta, is a method of testing cables to define the insulation condition of the underground cable. The phase shifts caused by the lossy current due to the existence of impurities in cable insulation is measured in this method. As most of distribution cables are long lengths, it becomes necessary to measure the tangent delta for these longer cables. In this paper, HFAC technique on longer length of good condition 11 KV power cables were used as samples to determine the tangent delta. Higher frequencies ( >100 Hz) were used to determine the tangent delta of cables at voltage of 1kV. The current (I) and phase theta were obtained in this experiment using HFAC measurement technique. CST Cable Suite software was used for simulating the experiment to verify the HFAC experimental setup by attaining sufficient dielectric current obtained through simulation and compare the leakage current values with the experimental values. The tangent delta results were attained for good cable with the length of 40 m, 70 m and 140 m and compared with 20 m length of good condition cable. The tangent delta results show that the HFAC technique is also applicable for the longer cable as well. � 2018 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo8641840
dc.identifier.doi10.1109/ICHVE.2018.8641840
dc.identifier.scopus2-s2.0-85063084950
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85063084950&doi=10.1109%2fICHVE.2018.8641840&partnerID=40&md5=f5c4fa94a21b23c32e31ade7dbdf5bbc
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/24783
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceScopus
dc.sourcetitleICHVE 2018 - 2018 IEEE International Conference on High Voltage Engineering and Application
dc.titleHigh Frequency Alternating Current (AC) Tangent Delta Measurement Technique for Underground Power Cable Systemen_US
dc.typeConference Paperen_US
dspace.entity.typePublication