Publication: Efficiency enhancement in energy production of photovoltaic modules through green roof installation under tropical climates
| dc.citedby | 2 | |
| dc.contributor.author | Arenandan V. | en_US |
| dc.contributor.author | Wong J.K. | en_US |
| dc.contributor.author | Ahmed A.N. | en_US |
| dc.contributor.author | Chow M.F. | en_US |
| dc.contributor.authorid | 57209317359 | en_US |
| dc.contributor.authorid | 57194870148 | en_US |
| dc.contributor.authorid | 57214837520 | en_US |
| dc.contributor.authorid | 57214146115 | en_US |
| dc.date.accessioned | 2023-05-29T09:36:38Z | |
| dc.date.available | 2023-05-29T09:36:38Z | |
| dc.date.issued | 2022 | |
| dc.description | Roofs; Solar power generation; Tropics; Building rooftop; Efficiency enhancement; Energy productions; Green roof; Performance; Photovoltaic modules; PV module temperature; PV system; Solar photovoltaics; Tropical climates; Solar cells | en_US |
| dc.description.abstract | This study is aimed to assess the performance of green roof-PV system; and determine the optimum installation height of green roof. In this study, two units PV panels of 1 kW each were setup at building rooftop level. Modular green roofs were established at three different heights of 0.3 m, 0.6 m and 0.9 m from rooftop floor level, respectively. The effects of each green roof height on the PV module temperature, ambient temperature and daily power yield were monitored for 6 months� period. The results showed that green roof-PV system exhibited lower ambient and PV module temperatures of 3.36% and 17% compared to bare roof-PV system. Other than that, green roof enhanced the power generation efficiency averagely by 1.6%. It is found that green roof installed at 0.3 m has increased the power generation performance by 3% and 11% compared to that of 0.6 m and 0.9 m, respectively. � 2022 | en_US |
| dc.description.nature | Final | en_US |
| dc.identifier.ArtNo | 101741 | |
| dc.identifier.doi | 10.1016/j.asej.2022.101741 | |
| dc.identifier.issue | 5 | |
| dc.identifier.scopus | 2-s2.0-85125445635 | |
| dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85125445635&doi=10.1016%2fj.asej.2022.101741&partnerID=40&md5=e47a08b7d0a0622b1539dd11da6a7aa7 | |
| dc.identifier.uri | https://irepository.uniten.edu.my/handle/123456789/26779 | |
| dc.identifier.volume | 13 | |
| dc.publisher | Ain Shams University | en_US |
| dc.source | Scopus | |
| dc.sourcetitle | Ain Shams Engineering Journal | |
| dc.title | Efficiency enhancement in energy production of photovoltaic modules through green roof installation under tropical climates | en_US |
| dc.type | Article | en_US |
| dspace.entity.type | Publication |