Publication:
Application of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran]

dc.contributor.authorKin C.M.en_US
dc.contributor.authorHwang T.Y.en_US
dc.contributor.authorShing W.L.en_US
dc.contributor.authorid57215027085en_US
dc.contributor.authorid57212768427en_US
dc.contributor.authorid55819849800en_US
dc.date.accessioned2023-05-29T08:14:04Z
dc.date.available2023-05-29T08:14:04Z
dc.date.issued2020
dc.description.abstractMicrowave-assisted extraction (MAE) coupled with dispersive liquid-liquid microextraction (DLLME) followed by gas-chromatography flame ionization detector (GC-FID) for the determination of 13 PAHs in vegetable samples was developed in this study. The analytical performances of the optimized DLLME and MAE-DLLME including limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, relative extraction recovery and relative extraction factor were validated and compared. The LOD of DLLME and MAE-DLLME were in the range of 0.040-0.400 and 0.0200-0.080 �g/L, respectively. For DLLME, precision and accuracy were 1.22-7.50% (RSD) and 71.77% to 90.93%, respectively; while for MAE-DLLME, were 0.77%-3.07% (RSD) and 83.65-98.42%, respectively. The relative extraction recovery was improved from 70.81% � 85.41% in DLLME to 85.79%-99.61% in MAE-DLLME. The relative enrichment factors were ranged from 126-156 and 165 to 202 for DLLME and MAE-DLLME, respectively. The volume of extraction solvent was reduced from 50 � L to 30 �L in MAE-DLLME. The overall analytical performances of MAE-DLLME is better than DLLME. The application of proposed MAE-DLLME in real samples was also investigated and discussed. � 2020, Malaysian Society of Analytical Sciences. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.epage61
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85079716131
dc.identifier.spage53
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85079716131&partnerID=40&md5=642fa21c67c80e78a57ed2f1be051a48
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25770
dc.identifier.volume24
dc.publisherMalaysian Society of Analytical Sciencesen_US
dc.sourceScopus
dc.sourcetitleMalaysian Journal of Analytical Sciences
dc.titleApplication of microwave-assisted extraction coupled with dispersive liquid-liquid microextraction for the determination of polycyclic aromatic hydrocarbons in vegetables [Aplikasi pengekstrakan berbantukan mikrogelombang gandingan dengan pengekstrakan mikro cecair-cecair serakan bagi penentukan hidrokarbon aromatik polisiklik dalam sayur-sayuran]en_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections