Publication:
Genetic Algorithm-Optimized Adaptive Network Fuzzy Inference System-Based VSG Controller for Sustainable Operation of Distribution System

dc.citedby1
dc.contributor.authorOthman M.H.en_US
dc.contributor.authorMokhlis H.en_US
dc.contributor.authorMubin M.en_US
dc.contributor.authorAb Aziz N.F.en_US
dc.contributor.authorMohamad H.en_US
dc.contributor.authorAhmad S.en_US
dc.contributor.authorMansor N.N.en_US
dc.contributor.authorid57214751187en_US
dc.contributor.authorid8136874200en_US
dc.contributor.authorid25930079700en_US
dc.contributor.authorid57221906825en_US
dc.contributor.authorid36809989400en_US
dc.contributor.authorid57192665072en_US
dc.contributor.authorid57114786800en_US
dc.date.accessioned2023-05-29T09:36:35Z
dc.date.available2023-05-29T09:36:35Z
dc.date.issued2022
dc.descriptionalternative energy; electricity supplyen_US
dc.description.abstractTo achieve a more sustainable supply of electricity and reduce dependency on fuels, the application of renewable energy sources-based distribution systems (DS) is stimulating. However, the intermittent nature of renewable sources reduces the overall inertia of the power system, which in turn seriously affects the frequency stability of the power system. A virtual synchronous generator can provide inertial response support to a DS. However, existing active power controllers of VSG are not optimized to react to the variation of frequency changes in the power system. Hence this paper introduces a new controller by incorporating GA-ANFIS in the active power controller to improve the performance of the VSG. The advantage of the proposed ANFIS-based controller is its ability to optimize the membership function in order to provide a better range and accuracy for the VSG responses. Rate of change of frequency (ROCOF) and change in frequency are used as the inputs of the proposed controller to control the values of two swing equation parameters, inertia constant (J) and damping constant (D). Two objective functions are used to optimize the membership function in the ANFIS. Transient simulation is carried out in PSCAD/EMTDC to validate the performance of the controller. For all the scenarios, VSG with GA-ANFIS (VOFIS) managed to maintain the DS frequency within the safe operating limit. A comparison between three other controllers proved that the proposed VSG controller is better than the other controller, with a transient response of 22% faster compared to the other controllers. � 2022 by the authors.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo10798
dc.identifier.doi10.3390/su141710798
dc.identifier.issue17
dc.identifier.scopus2-s2.0-85138286556
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85138286556&doi=10.3390%2fsu141710798&partnerID=40&md5=6b15c472f0e771307d1cd501438c82c1
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/26764
dc.identifier.volume14
dc.publisherMDPIen_US
dc.relation.ispartofAll Open Access, Gold
dc.sourceScopus
dc.sourcetitleSustainability (Switzerland)
dc.titleGenetic Algorithm-Optimized Adaptive Network Fuzzy Inference System-Based VSG Controller for Sustainable Operation of Distribution Systemen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections