Publication:
Detection of Inhibitor Content in Transformer Oil at Wavelengths below 1000 nm

dc.citedby3
dc.contributor.authorThiviyanathan V.A.en_US
dc.contributor.authorJern Ker P.en_US
dc.contributor.authorLeong Y.S.en_US
dc.contributor.authorAfini Fauzi N.en_US
dc.contributor.authorJamaludin M.Z.en_US
dc.contributor.authorLooe H.M.en_US
dc.contributor.authorLo C.K.en_US
dc.contributor.authorid57205077992en_US
dc.contributor.authorid37461740800en_US
dc.contributor.authorid57202929965en_US
dc.contributor.authorid57208664486en_US
dc.contributor.authorid57216839721en_US
dc.contributor.authorid6507460925en_US
dc.contributor.authorid36721595300en_US
dc.date.accessioned2023-05-29T07:25:52Z
dc.date.available2023-05-29T07:25:52Z
dc.date.issued2019
dc.descriptionPhotodetectors; Power transformers; Signal processing; Spectrophotometers; Continuous monitoring; Inhibitor content; Main transformer; Optical characterization; Optical detection methods; Power transmission and distributions; Silicon photo-detector; Transformer oil samples; Oil filled transformersen_US
dc.description.abstractPower transformers are significant in the power transmission and distribution network. A continuous monitoring of the transformer is crucial in ensuring a longer life spend service of the transformer. This paper focuses on the characterization of transformer oil using optical detection method at wavelengths below 1000 nm, which can be detected using Silicon photodetector. Transformer oil samples with 5 different concentrations of inhibitor content were prepared for the optical characterization from 950 nm to 970 nm. The results of the experiment show an excellent correlation between the concentration of inhibitor content in the oil and the magnitude of the peak absorbance at the 959 nm wavelength. This approach can potentially lead to the development of low cost and portable device that can measure the concentration of inhibitor of the transformer oil. � 2019 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo8696035
dc.identifier.doi10.1109/CSPA.2019.8696035
dc.identifier.epage89
dc.identifier.scopus2-s2.0-85065502408
dc.identifier.spage86
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85065502408&doi=10.1109%2fCSPA.2019.8696035&partnerID=40&md5=43a1cd13d190c4936f33a00a6e87a257
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/24687
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceScopus
dc.sourcetitleProceedings - 2019 IEEE 15th International Colloquium on Signal Processing and its Applications, CSPA 2019
dc.titleDetection of Inhibitor Content in Transformer Oil at Wavelengths below 1000 nmen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections