Publication:
Contamination of high voltage insulators in the east coast of Peninsular Malaysia

dc.citedby6
dc.contributor.authorAhmad A.S.en_US
dc.contributor.authorAhmad H.en_US
dc.contributor.authorJidin R.B.en_US
dc.contributor.authorTamsir T.en_US
dc.contributor.authorAhmed S.S.en_US
dc.contributor.authorBuntat Z.en_US
dc.contributor.authorid7202040740en_US
dc.contributor.authorid7102866725en_US
dc.contributor.authorid6508169028en_US
dc.contributor.authorid7801658692en_US
dc.contributor.authorid57193735776en_US
dc.contributor.authorid57194234727en_US
dc.date.accessioned2023-12-28T08:57:59Z
dc.date.available2023-12-28T08:57:59Z
dc.date.issued2000
dc.description.abstractRapid urbanization and industrialization in Malaysia over last two decades has resulted in increased demand for reliable electric power. The reliability in turn is greatly influenced by the grid system and its components being properly maintained. One of the important components is the high voltage insulators used in the switchyards, overhead lines, substations and power stations. A common phenomenon in the east cost of Peninsular Malaysia is rapid buildup of salt contamination on high voltage insulators due to the salty wind coming from the South China Sea. The main objective of this paper is to develop a mathematical model correlating Equivalent Salt Deposit Density (ESDD) with the hydrometeorological variables. The data collected at one of the plants in the east coast during the dry season has been used to develop the model by using multiple regression analysis. This model has been validated for predicting contamination accumulation level during the dry season. � 2000 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo898144
dc.identifier.doi10.1109/ICPST.2000.898144
dc.identifier.epage1228
dc.identifier.scopus2-s2.0-0005326257
dc.identifier.spage1223
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-0005326257&doi=10.1109%2fICPST.2000.898144&partnerID=40&md5=ea41a90e77d5eae1210eb11cd172c9ea
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/29863
dc.identifier.volume3
dc.pagecount5
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.sourceScopus
dc.sourcetitlePowerCon 2000 - 2000 International Conference on Power System Technology, Proceedings
dc.subjectContamination
dc.subjectESDD
dc.subjectHigh voltage
dc.subjectInsulators
dc.subjectRegression analysis
dc.subjectContamination
dc.subjectDrought
dc.subjectElectric insulators
dc.subjectRegression analysis
dc.subjectSalt deposits
dc.subjectEquivalent salt deposit density
dc.subjectESDD
dc.subjectHigh voltage
dc.subjectHigh voltage insulators
dc.subjectHydrometeorological variables
dc.subjectMultiple regression analysis
dc.subjectRapid urbanizations
dc.subjectReliable electric power
dc.subjectElectric insulation
dc.titleContamination of high voltage insulators in the east coast of Peninsular Malaysiaen_US