Publication:
Study of pipe thickness loss using a neutron radiography method

dc.citedby2
dc.contributor.authorMohamed A.A.en_US
dc.contributor.authorWahab A.A.B.en_US
dc.contributor.authorYazid H.B.en_US
dc.contributor.authorAhmad M.H.A.R.B.M.en_US
dc.contributor.authorJamro R.B.en_US
dc.contributor.authorAzman A.B.en_US
dc.contributor.authorZin M.R.M.en_US
dc.contributor.authorIdris F.M.en_US
dc.contributor.authorid57190936088en_US
dc.contributor.authorid56342608900en_US
dc.contributor.authorid22137189500en_US
dc.contributor.authorid55338850700en_US
dc.contributor.authorid23004755400en_US
dc.contributor.authorid24075556300en_US
dc.contributor.authorid36870000700en_US
dc.contributor.authorid6701397678en_US
dc.date.accessioned2023-05-16T02:46:54Z
dc.date.available2023-05-16T02:46:54Z
dc.date.issued2014
dc.description.abstractThe purpose of this preliminary work is to study for thickness changes in objects using neutron radiography. In doing the project, the technique for the radiography was studied. The experiment was done at NUR-2 facility at TRIGA research reactor in Malaysian Nuclear Agency, Malaysia. Test samples of varying materials were used in this project. The samples were radiographed using direct technique. Radiographic images were recorded using Nitrocellulose film. The films obtained were digitized to processed and analyzed. Digital processing is done on the images using software Isee!. The images were processed to produce better image for analysis. The thickness changes in the image were measured to be compared with real thickness of the objects. From the data collected, percentages difference between measured and real thickness are below than 2%. This is considerably very low variation from original values. Therefore, verifying the neutron radiography technique used in this project. © 2014 AIP Publishing LLC.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.1063/1.4866114
dc.identifier.epage113
dc.identifier.scopus2-s2.0-84906775579
dc.identifier.spage109
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84906775579&doi=10.1063%2f1.4866114&partnerID=40&md5=474b2bd7700ba57a4c6924cd874a5a5e
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/22044
dc.identifier.volume1584
dc.publisherAmerican Institute of Physics Inc.en_US
dc.relation.ispartofAll Open Access, Bronze
dc.sourceScopus
dc.sourcetitleAIP Conference Proceedings
dc.titleStudy of pipe thickness loss using a neutron radiography methoden_US
dc.typeConference Paperen_US
dspace.entity.typePublication