Publication:
Magnetic fields from a scaled down model transmission Line - Simulation and comparison to measurements

dc.citedby1
dc.contributor.authorRahman N.A.en_US
dc.contributor.authorHussain H.en_US
dc.contributor.authorSaid I.en_US
dc.contributor.authorJalal T.S.en_US
dc.contributor.authorFarag A.S.en_US
dc.contributor.authorid9338388000en_US
dc.contributor.authorid35607922800en_US
dc.contributor.authorid56186718000en_US
dc.contributor.authorid16022044400en_US
dc.contributor.authorid57208098840en_US
dc.date.accessioned2023-12-28T08:57:43Z
dc.date.available2023-12-28T08:57:43Z
dc.date.issued2005
dc.description.abstractThe last two decade had witnessed growing public concern over possible harmful effects of electric and magnetic fields emanated from electric power facilities and transmission lines. Numerous works examined magnetic fields emanating from conventionally designed transmission lines had been carried out. As the continuous and quality of supply is of utmost importance, changes to the actual line settings and configurations needed during a study are limited and difficult to make in order not to cause any interruption of supply especially to those sensitive areas. This paper reports the construction of a scaled down double circuit transmission line, the measurement results obtained and results of simulation study in order to assess the performance of an actual double circuit transmission line. It was found that the measured value corresponds well to the simulated value. The optimum phase arrangement is sought in view of the lowest peak magnetic field and the magnetic field at the edge of right-of-way. Others suggested usage of the scaled down model for the reduction of magnetic field such as using passive and active shielding are also presented. � 2005 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo1607795
dc.identifier.doi10.1109/APACE.2005.1607795
dc.identifier.epage151
dc.identifier.scopus2-s2.0-33847330774
dc.identifier.spage147
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-33847330774&doi=10.1109%2fAPACE.2005.1607795&partnerID=40&md5=32e5e6b9a50983f6ce50ab6f63d4bd58
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/29803
dc.identifier.volume2005
dc.pagecount4
dc.sourceScopus
dc.sourcetitle2005 Asia-Pacific Conference on Applied Electromagnetics, APACE 2005 - Proceedings
dc.subjectComputer simulation
dc.subjectElectric industry
dc.subjectElectric shielding
dc.subjectMagnetic fields
dc.subjectMathematical models
dc.subjectPhase measurement
dc.subjectActive shielding
dc.subjectDouble circuit transmission lines
dc.subjectElectric power facilities
dc.subjectScaled down models
dc.subjectElectric lines
dc.titleMagnetic fields from a scaled down model transmission Line - Simulation and comparison to measurementsen_US
dc.typeConference paperen_US
dspace.entity.typePublication
Files
Collections