Publication:
Integrated renewable energy micro-grid for meeting peak hours demand

dc.contributor.authorAznan K.A.en_US
dc.contributor.authorKhan S.en_US
dc.contributor.authorYaacob M.en_US
dc.contributor.authorKhalifa O.O.en_US
dc.contributor.authorAboadla E.en_US
dc.contributor.authorTohtayong M.en_US
dc.contributor.authorKhalil A.en_US
dc.contributor.authorMuhaisen N.A.N.en_US
dc.contributor.authorTan N.M.L.en_US
dc.contributor.authorid57200258723en_US
dc.contributor.authorid7404043105en_US
dc.contributor.authorid57189683123en_US
dc.contributor.authorid9942198800en_US
dc.contributor.authorid57189688922en_US
dc.contributor.authorid57193490068en_US
dc.contributor.authorid57200143769en_US
dc.contributor.authorid57193491937en_US
dc.contributor.authorid24537965000en_US
dc.date.accessioned2023-05-29T06:53:57Z
dc.date.available2023-05-29T06:53:57Z
dc.date.issued2018
dc.descriptionElectric utilities; Energy dissipation; Voltage distribution measurement; Alternative source; Conventional systems; Energy demands; Low voltage distribution network; Power demands; Renewable energies; Renewable energy source; Solar and winds; Renewable energy resourcesen_US
dc.description.abstractIn the TNB-based conventional system, the power demand varies randomly depending upon seasons and months of the year including festive occasions, reaching peak in some hours of days of some months. Sometime a heavy demand (in MW) falls at a time of a day. Such heavy energy demands need to be transported from far-away power stations over long lengthy transmissions causing energy loss not less than 20% in most of the cases. This paper presents load demand variation scenario, identifying peaks, and finally suggesting a strategy for meeting the peak demand from Renewable Energy Sources (RES) of solar and wind. An integrated RES-based microgrid is suggested with analytical and simulation results showing how the peak demand is being met from alternative sources of solar. The results of this paper find applications in suggesting RES-based generations for distributed locations within the low-voltage distribution network of Malaysian Electric Utility Tenaga Nasional Berhad. � 2018 Institution of Engineering and Technology. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.issueCP749
dc.identifier.scopus2-s2.0-85061395084
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85061395084&partnerID=40&md5=181daea4ea7a260cd606319ffaa88de2
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23989
dc.identifier.volume2018
dc.publisherInstitution of Engineering and Technologyen_US
dc.sourceScopus
dc.sourcetitleIET Conference Publications
dc.titleIntegrated renewable energy micro-grid for meeting peak hours demanden_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections