Publication:
Emf response on human body model caused by side flashes and earth potential rise

dc.contributor.authorZakaria N.A.en_US
dc.contributor.authorAli N.H.N.en_US
dc.contributor.authorNordin F.H.en_US
dc.contributor.authorMustafa N.B.A.en_US
dc.contributor.authorAmirulddin U.A.U.en_US
dc.contributor.authorKadir M.Z.A.A.en_US
dc.contributor.authorid57216460504en_US
dc.contributor.authorid57196922007en_US
dc.contributor.authorid25930510500en_US
dc.contributor.authorid57191952020en_US
dc.contributor.authorid26422804600en_US
dc.contributor.authorid25947297000en_US
dc.date.accessioned2023-05-29T08:10:22Z
dc.date.available2023-05-29T08:10:22Z
dc.date.issued2020
dc.description.abstractMost lightning fatalities take place in outdoor areas and it is reported that earth potential rise (EPR) contributes to the highest lighting injuries while side flash is the second highest. Due to the number of injuries caused by side flash and EPR events, there is a need to conduct thorough investigation on the electrical response to human body parts. Hence in this paper, the level of injuries on each body parts is determined based on the values and distributions of current, magnetic field, magnetic flux and energy produced by both EPR and side flash. Single line is generated from head to leg to measure the lightning effects on head, chest, hand and legs, which allow comparison to be made. The results show that side flash affects more on the upper part of the body while EPR affects more on the lower part of the body. However, individuals that are struck by EPR have higher probability to die compared to side flash since EPR produces higher value of current which is 0.032860 Wb/m on both feet compared to side flash, 0.01589 Wb/m on left hand which is more than the human body could withstand. � 2020 SERSC.en_US
dc.description.natureFinalen_US
dc.identifier.epage910
dc.identifier.issue6 Special Issue
dc.identifier.scopus2-s2.0-85083566881
dc.identifier.spage900
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85083566881&partnerID=40&md5=f24a3530d2249640d45ae582d346d272
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25513
dc.identifier.volume29
dc.publisherScience and Engineering Research Support Societyen_US
dc.sourceScopus
dc.sourcetitleInternational Journal of Advanced Science and Technology
dc.titleEmf response on human body model caused by side flashes and earth potential riseen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections