Publication:
Indoor-outdoor air quality assessment in nurseries

dc.contributor.authorMansor A.A.en_US
dc.contributor.authorHisham A.N.B.en_US
dc.contributor.authorAbdullah S.en_US
dc.contributor.authorMohd Napi N.N.L.en_US
dc.contributor.authorAhmed A.N.en_US
dc.contributor.authorIsmail M.en_US
dc.contributor.authorid57211858557en_US
dc.contributor.authorid57221754443en_US
dc.contributor.authorid56509029800en_US
dc.contributor.authorid57224902975en_US
dc.contributor.authorid57214837520en_US
dc.contributor.authorid57210403363en_US
dc.date.accessioned2023-05-29T08:06:37Z
dc.date.available2023-05-29T08:06:37Z
dc.date.issued2020
dc.descriptionAir quality; Carbon monoxide; Environmental technology; Indoor air pollution; Improving the environments; Indoor air quality; Indoor and outdoor airs; Indoor concentration; Monitored parameters; Outdoor air qualities; PM10 concentration; Public institution; Carbon dioxideen_US
dc.description.abstractPoor Indoor Air Quality (IAQ) can adversely affect children�s health, comfort and school performance. This study mainly aimed to assess indoor and outdoor air quality status in terms of physical and chemical aspects at nurseries of two higher public institutions. The monitored parameters are temperature (T), relative humidity (RH), air movement (AM), particulate matter (PM), carbon dioxide (CO2) and carbon monoxide (CO) by using Climomaster (RH, T, AM), Dust Trax� (RSP)and Kanomax IAQ (CO, CO2). The measurement was taken continuously in a period of three days at two nurseries of public institutions. Results show all chemicals contaminants at two nurseries did not exceed the standard except CO2 for indoor concentration. Indoor-Outdoor (I/O) ratio stated that PM10 concentrations were influenced by the outdoor contaminant for both study areas. In conclusion, this study provides useful information for engineers, policy makers and planners to make decision on managing and improving the environment in terms of air quality. � 2020 Institute of Physics Publishing. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo12001
dc.identifier.doi10.1088/1755-1315/616/1/012001
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85100008927
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85100008927&doi=10.1088%2f1755-1315%2f616%2f1%2f012001&partnerID=40&md5=1f5e44815534a037d9df41145c027f49
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25061
dc.identifier.volume616
dc.publisherIOP Publishing Ltden_US
dc.relation.ispartofAll Open Access, Bronze
dc.sourceScopus
dc.sourcetitleIOP Conference Series: Earth and Environmental Science
dc.titleIndoor-outdoor air quality assessment in nurseriesen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections