Publication:
The influence of addition of treated kenaf fibre in the production and properties of fibre reinforced foamed composite

dc.citedby40
dc.contributor.authorMahzabin M.S.en_US
dc.contributor.authorHock L.J.en_US
dc.contributor.authorHossain M.S.en_US
dc.contributor.authorKang L.S.en_US
dc.contributor.authorid56584655200en_US
dc.contributor.authorid56655789700en_US
dc.contributor.authorid55579596900en_US
dc.contributor.authorid25225738600en_US
dc.date.accessioned2023-05-29T06:51:30Z
dc.date.available2023-05-29T06:51:30Z
dc.date.issued2018
dc.descriptionAdhesion; Cements; Computer graphics; Concrete mixtures; Concrete products; Curing; Foamed products; Hemp; Kenaf fibers; Light weight concrete; Reinforcement; Scanning electron microscopy; Sodium hydroxide; Surface morphology; Surface roughness; Testing; Water absorption; Weathering; Accelerated weathering tests; Alkaline treatment; Durability property; Energy dispersive x-ray; Fibre reinforced; Industrial product; Initial surface absorptions; Optimal conditions; Durabilityen_US
dc.description.abstractThis paper describes the investigation of the influence of treatment of fibre on the durability properties includes drying shrinkage test, water absorption test, initial surface absorption test (ISAT), and accelerated weathering test (wet/dry cycling). Additionally, scanning electron microscopy with energy dispersive X-ray (SEM/EDX) analysis was carried out to study the surface morphology under magnified graphics of lightweight foamed concrete with the inclusion of both treated and untreated kenaf fibres. The foamed concrete mixture was set to a target density of 1250 kg/m3 with a tolerance of 75 kg/m3. The cement, sand and water ratio used was 1:1.5:0.45 with 0.45% volume fraction of kenaf fibre inclusion. Correspondingly, the most optimal condition to perform such treatment was studied based on previous researchers, in which the alkaline medium used was 6% sodium hydroxide (NaOH), followed by 12 h immersion period. The study on durability properties of kenaf fibre reinforced lightweight foamed concrete (KFLFC) helps to determine the suitable application for various industrial products in term of lifespan and functionality. The advantageous properties such as low in density and light in weight can reduce the self-weight of structure, by all means, lowering the project cost and time. In this project, the durability tests of the kenaf fibre reinforced lightweight foamed concrete (KFLFC) were conducted according to American Standard Testing Method (ASTM), British Standards (BS EN), and Eurocodes (EC EN). The results showed that alkaline treatment could clean and chemically modify the kenaf fibres surface morphology, rendering to increase in surface roughness which gives better surface adhesion between fibre and cement matrix in terms of adhesion, hydration process, and internal curing process. Similarly, SEM analysis indicating better adhesion of treated kenaf fibre with matrix and lower ductility. � 2018 Elsevier Ltden_US
dc.description.natureFinalen_US
dc.identifier.doi10.1016/j.conbuildmat.2018.05.169
dc.identifier.epage528
dc.identifier.scopus2-s2.0-85047505870
dc.identifier.spage518
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85047505870&doi=10.1016%2fj.conbuildmat.2018.05.169&partnerID=40&md5=88efc897fbbc8d3bf834022333606673
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23750
dc.identifier.volume178
dc.publisherElsevier Ltden_US
dc.sourceScopus
dc.sourcetitleConstruction and Building Materials
dc.titleThe influence of addition of treated kenaf fibre in the production and properties of fibre reinforced foamed compositeen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections