dc.description.abstractTangent Delta is a measurement technique to investigate cables insulation strength. Current techniques utilize Very Low Frequency (VLF) at 0.1 Hz and power frequency at 50 Hz. However, high voltages are required, thus requiring larger space and cost. Proposed method of tangent delta testing utilizes High frequency Low voltage diagnoses. The phase between the current and the voltage is utilized to determine the tangent delta (tan ?). The aim of this study is to develop a low voltage high frequency tangent delta measurement method and test if it can discriminate manufactured 132 kV good conditioned cable sample from defect induced cables with void, scotched and contamination in its insulation. Impurities are clearly discriminated using this method. Comparison of Tangent Delta of cables manufactured simultaneously in good condition and defect induced is performed using High Frequency Tangent Delta method and in 50 Hz conventional method to validate the effectiveness of the measurement technique. The High Frequency AC setup utilizes a small testing environment which can sample small lengths with minimum 1 m length of cable. The small lengths will result in the reduction of total capacitance of the cable but using High Frequency induces high electric stress on XLPE layer thus resulting in measureable dielectric current. � Maxwell Scientific Organization, 2015.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.19026/rjaset.10.2446
dc.identifier.epage913
dc.identifier.issue8
dc.identifier.scopus2-s2.0-84939216702
dc.identifier.spage903
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84939216702&doi=10.19026%2frjaset.10.2446&partnerID=40&md5=f35421f1f4d47796de889761cf48c8a3
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/22535
dc.identifier.volume10
dc.publisherMaxwell Science Publicationsen_US
dc.relation.ispartofAll Open Access, Gold
dc.sourceScopus
dc.sourcetitleResearch Journal of Applied Sciences, Engineering and Technology
dc.titleHigh frequency tan delta measurement method for 132kV transmission underground cablesen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections