Publication:
Influence of electrode geometry on the lightning impulse breakdown voltage of palm oil

dc.citedby9
dc.contributor.authorThien Y.V.en_US
dc.contributor.authorAzis N.en_US
dc.contributor.authorJasni J.en_US
dc.contributor.authorYunus R.en_US
dc.contributor.authorKadir M.Z.A.A.en_US
dc.contributor.authorYaakub Z.en_US
dc.contributor.authorid56602865000en_US
dc.contributor.authorid56120698200en_US
dc.contributor.authorid25632671500en_US
dc.contributor.authorid6603243672en_US
dc.contributor.authorid25947297000en_US
dc.contributor.authorid56602940600en_US
dc.date.accessioned2023-05-29T06:49:59Z
dc.date.available2023-05-29T06:49:59Z
dc.date.issued2018
dc.descriptionElectric breakdown; Electrodes; Geometry; Lightning; Mineral oils; Needles; Oil filled transformers; Electrode configurations; Electrode geometries; Gap distances; Lightning impulse breakdown; Negative polarity; transformer; Voltage polarity; Palm oilen_US
dc.description.abstractThis paper presents a study of lightning impulse breakdown voltage of palm oil under needle/plane and needle/sphere electrode configurations. All tests were carried out at gap distance of 25 mm under both positive and negative polarities. Two types of palm oil and mineral oil were used in this study. The results show that the different electrode geometry has significant impact on the lightning impulse breakdown voltage. It was found that needle/plane geometry has lower breakdown voltage than needle/sphere. The voltage polarity also showed some influence on the lightning breakdown voltage for all fluid samples. Comparing both positive and negative polarities, the percentage of difference between all samples is much higher under needle/plane electrode configuration which can be up to 43%. The positive mean lightning breakdown voltage of palm oil is comparable with the mineral oil. � 2018 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo8566615
dc.identifier.doi10.1109/APPEEC.2018.8566615
dc.identifier.epage320
dc.identifier.scopus2-s2.0-85060365834
dc.identifier.spage317
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85060365834&doi=10.1109%2fAPPEEC.2018.8566615&partnerID=40&md5=d526ff86cf34e90c8698e99d19a26b32
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23507
dc.identifier.volume2018-October
dc.publisherIEEE Computer Societyen_US
dc.relation.ispartofAll Open Access, Green
dc.sourceScopus
dc.sourcetitleAsia-Pacific Power and Energy Engineering Conference, APPEEC
dc.titleInfluence of electrode geometry on the lightning impulse breakdown voltage of palm oilen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files