Publication:
Embedded Connectors to Eliminate Debonding of Steel Plate for Optimal Shear Strengthening of RC Beam

dc.citedby8
dc.contributor.authorAlam M.A.en_US
dc.contributor.authorSami A.en_US
dc.contributor.authorMustapha K.N.en_US
dc.contributor.authorid57199298044en_US
dc.contributor.authorid56443764700en_US
dc.contributor.authorid26032672000en_US
dc.date.accessioned2023-05-29T06:37:55Z
dc.date.available2023-05-29T06:37:55Z
dc.date.issued2017
dc.description.abstractExternally bonded method would be the most potential technique for optimal shear strengthening of deficient reinforced concrete (RC) beam subjected to eliminate premature debonding failure. The main aim of this research was to eliminate debonding failure of steel plate using embedded connector systems for optimal shear strengthening of RC beam. Dimensions of steel plates were optimized based on the proposed design guideline in accordance with EC2. The strengthened beams with connectors were then compared with those of U-jacketing system. Bond strength enhancements of steel plate using connectors were experimentally investigated through pullout test of prisms. The beam specimens were fabricated and tested to investigate the effects of embedded connectors. Result showed that steel bar and adhesive embedded connectors significantly increased the bond strength of externally bonded plates. The connectors completely prevented premature debonding failure of steel plates and allowed the beams to fail by flexure with full ductility and strength, whereas U-jacket showed the premature debonding of plates. The embedded connectors optimized/reduced the dimension of the externally bonded steel plate by 60% as compared to those of arbitrarily strengthened beam. The experimental results satisfactorily verified the proposed design guideline. � 2017, King Fahd University of Petroleum & Minerals.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.1007/s13369-017-2572-5
dc.identifier.epage4068
dc.identifier.issue9
dc.identifier.scopus2-s2.0-85027867000
dc.identifier.spage4053
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85027867000&doi=10.1007%2fs13369-017-2572-5&partnerID=40&md5=41bc5559219434026f8b300dcd87f0c9
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23133
dc.identifier.volume42
dc.publisherSpringer Verlagen_US
dc.sourceScopus
dc.sourcetitleArabian Journal for Science and Engineering
dc.titleEmbedded Connectors to Eliminate Debonding of Steel Plate for Optimal Shear Strengthening of RC Beamen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections