Publication:
Minimum separation between lightning protection system and non-integrated metallic structures

dc.citedby4
dc.contributor.authorFallah S.N.en_US
dc.contributor.authorGomes C.en_US
dc.contributor.authorIzadi M.en_US
dc.contributor.authorKadir M.Z.A.A.en_US
dc.contributor.authorAhmed R.J.en_US
dc.contributor.authorJasni J.B.en_US
dc.contributor.authorid35174161400en_US
dc.contributor.authorid57201335285en_US
dc.contributor.authorid56406980700en_US
dc.contributor.authorid25947297000en_US
dc.contributor.authorid55832246700en_US
dc.contributor.authorid25632671500en_US
dc.date.accessioned2023-05-29T06:50:40Z
dc.date.available2023-05-29T06:50:40Z
dc.date.issued2018
dc.descriptionLightning protection; Metals; Roofs; Air-termination systems; constant area criterion; Direct lightning strikes; Electronic systems; Lightning protection systems; Metallic component; Metallic structures; Separation distances; Lightningen_US
dc.description.abstractIn the event of a direct lightning strike to a protected building which is integrated with an electrical or electronic system installed on the roof such as roof-top PV system, dangerous arcing may occur between the external lightning protection system (LPS) and the conductive components of the electrical system. To prevent such side flashes, a minimum separation distance between the metallic components and the air termination system is required. Even though, IEC62305-3 Standard provides a formula to specify the necessary separation distance, so far there is no extensive study that has been done to evaluate the suitability of the application of equation to calculate the separation distance, specifically to the safety of electrical systems integrated into the roof top of building. In this study, a new computational method has been developed for calculation of the separation distance between an LPS and metallic components on the roof. In the proposed method which is based on the theoretical background of the IEC62305-3 Standard formula, the break down behavior of the gap geometry between the LPS and the metallic components for the applied voltage across the gap is analyzed. PSCAD software was used to model the LPS and the lightning strokes. � 2018 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo8503276
dc.identifier.doi10.1109/ICLP.2018.8503276
dc.identifier.scopus2-s2.0-85056833953
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85056833953&doi=10.1109%2fICLP.2018.8503276&partnerID=40&md5=7807dc7e506bc3a9ce979f060e90c48d
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23640
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartofAll Open Access, Green
dc.sourceScopus
dc.sourcetitle34th International Conference on Lightning Protection, ICLP 2018
dc.titleMinimum separation between lightning protection system and non-integrated metallic structuresen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections