Publication:
Optimization of Rhombus Opening Area of Shear Walls On Tall Buildings

dc.citedby0
dc.contributor.authorSyamsir A.en_US
dc.contributor.authorIskandar I.en_US
dc.contributor.authorMalekzadah A.R.en_US
dc.contributor.authorAlhayek A.en_US
dc.contributor.authorid57195320482en_US
dc.contributor.authorid57216039120en_US
dc.contributor.authorid58186454400en_US
dc.contributor.authorid57221437286en_US
dc.date.accessioned2024-10-14T03:22:06Z
dc.date.available2024-10-14T03:22:06Z
dc.date.issued2023
dc.description.abstractThis research was designed to determine the optimum percentage and configuration of rhombus opening on shear wall of tall building. A residential tall building of 12-storeys having base size of 20m x 10m with height of floor of 3m was analyzed. In this paper, percentages of 12%, 24%, 36%, 42%, and 54% concentric rhombus opening in a shear wall in tall buildings were modeled. The effect of the opening size on the lateral displacement, base shear, and stress at the opening was determined. It was found that the opening of 12% has less lateral displacement, base shear, and stress at the opening. This indicates that this opening delivers the best performance among the other percentages. Five models with the same percentage of rhombus opening of 12% at different configuration on the shear wall in tall buildings were modeled to determine the optimum configuration of opening on shear walls. It was found that Model-1 is the optimum configuration since this model has the lowest lateral displacement and stress at the opening. It can be concluded that Model-1 with 12% opening area is the optimum size and configuration to resist lateral force on tall buildings. � 2023 UTHM Publisher. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.30880/ijie.2023.15.01.033
dc.identifier.epage376
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85152672336
dc.identifier.spage367
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85152672336&doi=10.30880%2fijie.2023.15.01.033&partnerID=40&md5=9144502664b6ef8921a4eea1930055f4
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/34727
dc.identifier.volume15
dc.pagecount9
dc.publisherPenerbit UTHMen_US
dc.relation.ispartofAll Open Access
dc.relation.ispartofBronze Open Access
dc.relation.ispartofGreen Open Access
dc.sourceScopus
dc.sourcetitleInternational Journal of Integrated Engineering
dc.subjectbase shear force
dc.subjectlateral displacement
dc.subjectrhombus opening
dc.subjectShear wall
dc.subjecttall building
dc.titleOptimization of Rhombus Opening Area of Shear Walls On Tall Buildingsen_US
dc.typeArticleen_US
dspace.entity.typePublication