Publication:
Determining the number of parallel RC branches in polarization/depolarization current modeling for XLPE cable insulation

dc.citedby7
dc.contributor.authorSulaiman S.en_US
dc.contributor.authorMohd Ariffin A.en_US
dc.contributor.authorKien D.T.en_US
dc.contributor.authorid36562570400en_US
dc.contributor.authorid16400722400en_US
dc.contributor.authorid55349294400en_US
dc.date.accessioned2023-05-29T06:40:29Z
dc.date.available2023-05-29T06:40:29Z
dc.date.issued2017
dc.description.abstractAn important element in the electric power distribution system is the underground cable. However continuous applications of high voltages unto the cable may lead to insulation degradations and subsequent cable failure. Since any disruption to the electricity supply may lead to economic losses as well as lowering customer satisfaction, the maintenance of cables is very important to an electrical utility company. Thus, a reliable diagnostic technique that is able to accurately assess the condition of cable insulation operating is critical, in order for cable replacement exercise to be done. One such diagnostic technique to assess the level of degradation within the cable insulation is the Polarization/Depolarization Current (PDC) analysis. This research work attempts to investigate PDC behaviour for medium voltage (MV) cross-linked polyethylene (XLPE) insulated cables, via baseline PDC measurements and utilizing the measured data to simulate for PDC analysis. Once PDC simulations have been achieved, the values of conductivity of XLPE cable insulations can be approximated. Cable conductivity serves as an indicator of the level of degradation of XLPE cable insulation. It was found that for new and unused XLPE cables, the polarization and depolarization currents have almost overlapping trendlines, as the cable insulation's conduction current is negligible. Using a linear dielectric circuit equivalence model as the XLPE cable insulation and its corresponding governing equations, it is possible to optimize the number of parallel RC branches to simulate PDC analysis, with a very high degree of accuracy. The PDC simulation model has been validated against the baseline PDC measurements.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.18517/ijaseit.7.3.2325
dc.identifier.epage979
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85021054440
dc.identifier.spage971
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85021054440&doi=10.18517%2fijaseit.7.3.2325&partnerID=40&md5=aae875ecc01c05277d994c13b0be6e0b
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23436
dc.identifier.volume7
dc.publisherInsight Societyen_US
dc.relation.ispartofAll Open Access, Hybrid Gold
dc.sourceScopus
dc.sourcetitleInternational Journal on Advanced Science, Engineering and Information Technology
dc.titleDetermining the number of parallel RC branches in polarization/depolarization current modeling for XLPE cable insulationen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections