Publication:
Frequency spectral analysis of electrical partial discharge signals in XLPE cable under various soil conditions

dc.citedby2
dc.contributor.authorMd Thayoob Y.H.en_US
dc.contributor.authorGhosh P.S.en_US
dc.contributor.authorGhani A.B.A.en_US
dc.contributor.authorid6505876050en_US
dc.contributor.authorid55427760300en_US
dc.contributor.authorid24469638000en_US
dc.date.accessioned2023-12-29T07:56:58Z
dc.date.available2023-12-29T07:56:58Z
dc.date.issued2008
dc.description.abstractAs XLPE cables age, partial discharge (PD) testing on the cables has gained a lot of attention in the power utilities. This is because PD has been found to be a good indicator of the insulation health. In this research work, an experiment has been carried out in order to acquire electrical PD signals from an 11KV, single-core 240mm2 XLPE cable. The operating conditions are varied using two parameters which are the soil thermal resistivity and cable loading in terms of core temperature. The analysis of PD signals has been commonly carried out in the time domain. However, in this paper, the analysis of PD signal patterns in an XLPE cable due to various soil conditions is performed in the frequency domain. As such, the timedomain electrical PD signals from the PD measurement system are first transformed into frequency spectrum using fast Fourier transform (FFT). Then, the variations in the spectral content due to the changes in the soil condition at a fixed temperature of the cable are analyzed. From the results obtained, it is clearly evident that the changes in the soil thermal resistivity have significant effect on the spectral content of the PD signals. � 2008 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo4762713
dc.identifier.doi10.1109/PECON.2008.4762713
dc.identifier.epage1531
dc.identifier.scopus2-s2.0-63049135081
dc.identifier.spage1528
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-63049135081&doi=10.1109%2fPECON.2008.4762713&partnerID=40&md5=a3dd185caf990e579f4c3147f62858c5
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/30970
dc.pagecount3
dc.sourceScopus
dc.sourcetitlePECon 2008 - 2008 IEEE 2nd International Power and Energy Conference
dc.subjectPartial discharge
dc.subjectSoil thermal resistivity
dc.subjectXLPE Cable
dc.subjectCables
dc.subjectFast Fourier transforms
dc.subjectFrequency domain analysis
dc.subjectPartial discharges
dc.subjectSoils
dc.subjectSpectrum analysis
dc.subjectSpectrum analyzers
dc.subjectThermal conductivity
dc.subjectTime domain analysis
dc.subjectCore temperatures
dc.subjectFixed temperatures
dc.subjectFrequency domains
dc.subjectFrequency spectrums
dc.subjectOperating conditions
dc.subjectPartial discharge signals
dc.subjectPD measurements
dc.subjectPower utilities
dc.subjectSignal patterns
dc.subjectSoil conditions
dc.subjectSpectral analysis
dc.subjectSpectral contents
dc.subjectTime domains
dc.subjectTwo parameters
dc.subjectXLPE Cable
dc.subjectElectric network analysis
dc.titleFrequency spectral analysis of electrical partial discharge signals in XLPE cable under various soil conditionsen_US
dc.typeConference paperen_US
dspace.entity.typePublication
Files
Collections