Publication:
Experimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climates

dc.citedby2
dc.contributor.authorAbdullah K.en_US
dc.contributor.authorSaepul Uyun A.en_US
dc.contributor.authorMuhammad Nur S.en_US
dc.contributor.authorBamahry A.en_US
dc.contributor.authorImanda R.en_US
dc.contributor.authorMeurah Indra Mahlia T.en_US
dc.contributor.authorid55973139100en_US
dc.contributor.authorid16067509800en_US
dc.contributor.authorid57202005106en_US
dc.contributor.authorid57202009673en_US
dc.contributor.authorid57217953192en_US
dc.contributor.authorid56997615100en_US
dc.date.accessioned2023-05-29T06:52:15Z
dc.date.available2023-05-29T06:52:15Z
dc.date.issued2018
dc.descriptionDriers (materials); Environmental impact; Evaporative cooling systems; Refrigerants; Thermoelectric equipment; Desiccant cooling; Desiccant cooling systems; Desiccant wheels; Evaporative cooling; Experimental investigations; Humidity conditions; Laboratory conditions; Tropical countries; Air conditioningen_US
dc.description.abstractIndonesia lies in the tropical climate which requires air conditioning to increase working productivity of the people. Up to now people are still using the compressive cooling system which uses Freon as the refrigerant, which have been known to have a negative environmental impact. Therefore, new cooling system which is environmentally friendly is now needed. Desiccant cooling system manipulates the humidity condition of outside air in such a way so that the final temperature should become at 25 �C and RH of 65 %. Since it does not require refrigerant, a desiccant cooling has the potential to be developed in a tropical country like Indonesia. In this study an experimental desiccant cooling system has been designed and constructed and tested under laboratory condition. Experimental results have shown that the resulting air temperature was 26.1 �C with RH of 55.6 %, and average cooling capacity was 0.425 kW. The COP was found to be 0.44. � The Authors, published by EDP Sciences, 2018.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo1022
dc.identifier.doi10.1051/matecconf/201816401022
dc.identifier.scopus2-s2.0-85046771668
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85046771668&doi=10.1051%2fmatecconf%2f201816401022&partnerID=40&md5=9a4f0afb54d4db87aead46d77a65b1ef
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/23834
dc.identifier.volume164
dc.publisherEDP Sciencesen_US
dc.relation.ispartofAll Open Access, Gold, Green
dc.sourceScopus
dc.sourcetitleMATEC Web of Conferences
dc.titleExperimental Investigation of Air Conditioner using the Desiccant Cooling System in Equatorial Climatesen_US
dc.typeConference Paperen_US
dspace.entity.typePublication
Files
Collections