Publication:
Performance assessment of a 619kW photovoltaic power plant in the northeast of peninsular Malaysia

dc.citedby2
dc.contributor.authorRaj M.N.en_US
dc.contributor.authorPasupuleti J.en_US
dc.contributor.authorid57218204609en_US
dc.contributor.authorid11340187300en_US
dc.date.accessioned2023-05-29T08:07:24Z
dc.date.available2023-05-29T08:07:24Z
dc.date.issued2020
dc.description.abstractPhotovoltaic (PV) power plants are becoming widely implemented and in larger scale around the world. Understanding performance criteria is crucial in the benchmark of PV plants and ascertaining performance requirements during both design and operational stage of a PV plant. Performance ratio (PR) and capacity factor (CF) are two generally accepted benchmarks for the assessment of a grid connected PV plant. However, within the South East Asia region, and especially within Malaysia, there is a lack of compilation and benchmark for the PR and CF values of existing and operational PV plants. This lack of data is disadvantageous for the designing and assessment of performance of any PV plants in the area. Thus, the focus of this study is to assess the PR and CF performance a 619kW PV plant in the Northeast of Peninsular Malaysia, with the ultimate goal of proposing a standard. From the continuous operation of the said PV plant for the duration of one year, the plant energy production has been obtained and is compared with the simulated energy generation model. Based on the comparison, the plant is determined to be operating with PR value of 0.77 and CF value of 12%. The plant is evaluated to be operating within benchmark values. These values not only verify the performance of the studied PV plant, they also present a form of comparison for future studies. � 2020 Institute of Advanced Engineering and Science. All rights reserved.en_US
dc.description.natureFinalen_US
dc.identifier.doi10.11591/ijeecs.v20.i1.pp9-15
dc.identifier.epage15
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85088250045
dc.identifier.spage9
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85088250045&doi=10.11591%2fijeecs.v20.i1.pp9-15&partnerID=40&md5=79cf5a684a8fce288ba3dd08775f41aa
dc.identifier.urihttps://irepository.uniten.edu.my/handle/123456789/25215
dc.identifier.volume20
dc.publisherInstitute of Advanced Engineering and Scienceen_US
dc.relation.ispartofAll Open Access, Gold, Green
dc.sourceScopus
dc.sourcetitleIndonesian Journal of Electrical Engineering and Computer Science
dc.titlePerformance assessment of a 619kW photovoltaic power plant in the northeast of peninsular Malaysiaen_US
dc.typeArticleen_US
dspace.entity.typePublication
Files
Collections