Publication: Experimental discussions on operating frequencies of a bidirectional isolated DC-DC converter for a battery energy storage system
dc.citedby | 12 | |
dc.contributor.author | Tan N.M.L. | en_US |
dc.contributor.author | Abe T. | en_US |
dc.contributor.author | Akagi H. | en_US |
dc.contributor.authorid | 24537965000 | en_US |
dc.contributor.authorid | 7406009689 | en_US |
dc.contributor.authorid | 7102912290 | en_US |
dc.date.accessioned | 2023-12-29T07:44:05Z | |
dc.date.available | 2023-12-29T07:44:05Z | |
dc.date.issued | 2013 | |
dc.description.abstract | This paper presents a high-efficiency bidirectional isolated dc-dc converter for a battery energy storage system connected to the grid. It discusses the design of the converter, an optimal operating frequency range, and the optimal dead times for a 6-kW, full-bridge, bidirectional isolated dc-dc converter with focus on improving converter efficiency. This paper also provides a power-loss breakdown of the dc-dc converter at the rated power. The optimal frequency range of the dc-dc converter is defined by making its frequency-dependent loss equal to its frequency-independent loss. The optimal dead time is defined by one-fourth of the resonant period. The maximum efficiency of the dc-dc converter operating at 4 kHz is measured at 98.1% during battery charging and at 98.2% during battery discharging. The converter maintains a high efficiency of more than 97% in a wide range of power transfer. � 2013 IEEE. | en_US |
dc.description.nature | Final | en_US |
dc.identifier.ArtNo | 6646999 | |
dc.identifier.doi | 10.1109/ECCE.2013.6646999 | |
dc.identifier.epage | 2340 | |
dc.identifier.scopus | 2-s2.0-84891106082 | |
dc.identifier.spage | 2333 | |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84891106082&doi=10.1109%2fECCE.2013.6646999&partnerID=40&md5=b631f8bf8791230af9a63799d1a5690e | |
dc.identifier.uri | https://irepository.uniten.edu.my/handle/123456789/30029 | |
dc.pagecount | 7 | |
dc.source | Scopus | |
dc.sourcetitle | 2013 IEEE Energy Conversion Congress and Exposition, ECCE 2013 | |
dc.subject | DC-DC converters | |
dc.subject | Efficiency | |
dc.subject | Electric drives | |
dc.subject | Energy conversion | |
dc.subject | Energy storage | |
dc.subject | Optimization | |
dc.subject | Battery energy storage systems | |
dc.subject | Bidirectional isolated dc-dc converter | |
dc.subject | Converter efficiency | |
dc.subject | Frequency-dependent loss | |
dc.subject | Maximum Efficiency | |
dc.subject | Operating frequency | |
dc.subject | Optimal frequency | |
dc.subject | Power transfers | |
dc.subject | HVDC power transmission | |
dc.title | Experimental discussions on operating frequencies of a bidirectional isolated DC-DC converter for a battery energy storage system | en_US |
dc.type | Conference paper | en_US |
dspace.entity.type | Publication |